The microscope is designed for studying specimens using the fluorescence microscopy technique in reflected light and brightfield technique in transmitted light. The additional equipment allows for darkfield polarization and phase contrast microscopy. Fluorescence microscopy is based on the ability of some substances to glow when exposed to the light of a certain part of the spectrum. The specimens are exposed to invisible short-wave ultraviolet light or violet blue and green light. The wavelength of the emitted light will be longer than the wavelength of the excitation light. The specimen glows blue cyan green-yellow or red light respectively. Some specimens glow by themselves while others glow after treatment with fluorochromes. The fluorescent microscope is used to study pathogens of tuberculosis chlamydia rabies herpes and other diseases. The microscope can also be used for DNA and chromosome analysis bone marrow and blood smears forensic and pharmacological examination veterinary control studies and sanitary and epidemiological inspection.

Microscope head

Trinocular head with infinity-corrected optics. Eyepiece tubes can rotate 360°. The user can adjust eye relief on the eyepiece to fit their height. The digital camera is mounted in the trinocular tube.

Revolving nosepiece

Five objectives. A free slot is used for centering the reflected light source. An additional objective can also be installed in the free slot in order to achieve extra magnification. The revolving nosepiece with objectives is oriented toward the interior – the user can see the objective inserted into the optical path and the space above the stage is free.

Objectives

Infinity plan achromatic objectives and infinity plan fluorite objectives. Standard configuration includes 4x 10x and 100x objectives for brightfield microscopy and a 40x objective for fluorescence microscopy.

Focusing mechanism

Coaxial coarse and fine focusing knobs are located at the base of the microscope on both sides. The user can place their hands on the table and take a relaxed pose while observing. The focusing adjustment is smooth and effortless. On the right there is a coarse focusing lock knob for quick adjustments after changing the specimen. On the left there is a coarse tension adjustment ring for further adjustment.

Stage

The stage does not have an X-axis positioning rack which ensures its ergonomic operation. The mechanical stage with a belt-driven mechanism allows for the smooth movement of the object. The slide holder is fixed with two screws and can be removed for easy operation. For reflected light observations a black stage plate should be placed on the stage to remove stray light.

Reflected light illuminator

The fluorescence excitation source is a 100W mercury lamp. It is extremely bright and has a wide spectrum of wavelengths. The mercury lamp has discrete peaks allowing you to work with many fluorochromes. The reflected light illuminator contains four excitation filters: ultraviolet (UV) violet (V) blue (B) and green (G). The mercury lamp is located in the lamphouse and can be centered in three planes. The heat radiation is conducted away from the lamphouse so that the lamp does not overheat. There is a mount that allows for safe and quick lamp replacement.

Köhler illumination in reflected and transmitted light

Setting up the Köhler illumination enhances the image quality of a specimen. With such illumination you can achieve maximum resolution on each objective and uniform illumination of the field of view with no darkening at the edges. The object of study is in sharp focus and the image artifacts are removed.

Condenser

The condenser has a slot for a darkfield slider or a phase contrast slider. The usage of slider saves time when switching between microscopy techniques in transmitted light.

Transmitted light source

The transmitted light illuminator has a 30W halogen bulb. Halogen bulbs emit light with a color temperature that allows for comfortable work. The 30W bulb is bright enough to observe using 4x to 100x magnification objectives.

Accessories

There is a line of accessories designed for the microscope. Optional objectives provide additional magnification. The optional 10x/0.35 fluorite objective is used for capturing an image of a specimen with a resolution of 0.5μm over a large field of view. Eyepieces that extend the magnification range of the microscope. Optional eyepieces help you maximize the potential of the objective you use most often. A phase contrast device a darkfield condenser and a polarization device offer more microscopy techniques so that you can study the specimens that are invisible in brightfield or fluorescent light. A digital camera that outputs the microscope image on a monitor and stores files along with software that takes real-time measurements of specimens. A calibration slide for measuring objects that can be combined with an eyepiece with a scale or the camera software.

Key features:

  • Study of specimens emitting fluorescence when exposed to excitation light
  • Microscopy techniques: fluorescence in reflected light brightfield in transmitted light
  • Trinocular head with adjustable eye relief and a vertical tube for mounting a digital camera
  • Reflected light illuminator: 100W mercury lamp of a wide wavelength spectrum
  • Fluorescence filters: ultraviolet (UV) violet (V) blue (B) green (G)
  • Transmitted light illuminator: 30W halogen bulb providing bright natural light
  • Köhler illumination in reflected and transmitted light
  • Simple stage without a positioning rack
  • Wide range of compatible optional accessories

The kit includes:

  • Base with a power input transmitted light source and condenser focusing mechanism stage and revolving nosepiece
  • Reflected light illuminator
  • Mercury lamphouse
  • Trinocular head
  • Infinity plan achromatic objective: PL 4x/0.10 WD 19.8mm
  • Infinity plan achromatic objective: PL 10x/0.25 WD 5.0mm
  • Infinity plan achromatic objective fluo: PL FL 40x/0.85 (spring-loaded) WD 0.42mm
  • Infinity plan achromatic objective fluo: PL 100x/1.25 (spring-loaded oil) WD 0.36mm
  • Eyepiece 10x/22mm with long eye relief (2 pcs.)
  • UV shield
  • C-mount adapter 1x
  • Hex key wrench
  • Mercury lamphouse power supply
  • Power cord
  • Reflected light illuminator power cord
  • Dust cover
  • User manual and warranty card

Available on request:

  • 10x/22mm eyepiece with a scale
  • 12.5x/14mm eyepiece (2 pcs.)
  • 15x/15mm eyepiece (2 pcs.)
  • 20x/12mm eyepiece (2 pcs.)
  • 25x/9mm eyepiece (2 pcs.)
  • Infinity plan achromatic objective fluo: PL FL 10x/0.35 WD 2.37mm
  • Infinity plan achromatic objective: PL 60x/0.80 ∞/0.17 WD 0.46mm
  • Phase contrast device
  • Darkfield condenser
  • Immersion darkfield condenser
  • Darkfield slider
  • Polarization device
  • Digital camera
  • Calibration slide
Brand MAGUS
Warranty years 5
EAN 5905555018140
Package size (LxWxH) cm 45.2x30.2x96
Shipping Weight kg 16.5
Head trinocular
Revolving nosepiece for 5 objectives
Objectives infinity plan achromatic and infinity plan achromatic fluo: PL 4x/0.10; PL 10x/0.25; PL FL 40x/0.85; PL 100x/1.25 (oil); parfocal distance: 45mm (*optional: PL FL 10x/0.35; PL 60x/0.80 ∞/0.17)
Working distance mm 19.8 (4x); 5.0 (10x); 0.42 (FL 40x); 0.36 (100x); 2.37 (FL 10х); 0.46 (60х)
Stage mm 180x150
Stage moving range mm 75/50
Condenser Abbe condenser N.A. 1.25 center-adjustable height-adjustable adjustable aperture diaphragm a slot for a darkfield slider and phase contrast slider dovetail mount
Diaphragm adjustable aperture diaphragm adjustable iris field diaphragm
Focus coaxial coarse focusing (21mm 39.8mm/circle with a lock knob and tension adjusting knob) and fine focusing (0.002mm)
Brightness adjustment yes
Operating temperature range °C 5 — 35
Assembly and installation difficulty level complicated
Illumination location dual
Fluorescent module filters: ultraviolet (UV) violet (V) blue (B) green (G)
Fluorescence filter: filter type excitation wavelength/dichroic mirror/emission wavelength ultraviolet (UV) 320–380nm/425 nm/435 nm; violet (V) 380–415nm/455nm/475nm; blue (B) 450–490nm/505nm/515nm; green (G) 495–555nm/585nm/595nm
Light source type reflected light: mercury lamp 100W; transmitted light: 12V 30W halogen bulb
Interpupillary distance mm 48 — 75
Type biological light/optical
Nozzle Gemel head (Siedentopf 360° rotation)
Magnification x 40–1000 basic (*optional: 40–1250/1500/2000/2500)
Eyepiece tube diameter mm 30
Eyepieces 10х/22mm eye relief: 10mm (*optional: 10x/22mm with scale 12.5x/14; 15x/15; 20x/12; 25x/9)
Stage features two-axis mechanical stage without a positioning rack
Illumination halogen fluorescent
Power supply AC network 85–265V 50/60Hz
Ability to connect additional equipment phase contrast device (condenser and objectives) darkfield condenser (dry or oil) polarization devices (polarizer and analyzer) darkfield slider
User level experienced users professionals
Application laboratory/medical
Research method bright field fluorescence
Pouch/case/bag in set dust cover

Returns Policy

We have a 14-day return policy. If you are not satisfied with your purchase, please return it in its original packaging and be sure to put the original product packaging inside the shipping box to avoid any damage..

All items must be in their original condition and unused. The value of your purchase will be refunded. .

Shipping charges will not be refunded.

If the return is due to a defective product, you may be compensated for the return shipping.

Please contact us for more details if you need to make a return..

SHIPPING POLICY

- From 0 to 2 kg - shipping cost: 12,50 euros.

- From 2.001 kg to 30 kg - shipping cost: 17,00 euros.

- From 30,001 kg - shipping cost: 30,00 euros.

In case of collection at our warehouse or resale points - the shipping is free.

Related Products