The Ermenrich Zing DZ60 is a True RMS digital clamp meter that is designed for building maintenance engineers, data center specialists, and HVAC (heating, ventilation, and air conditioning) technicians. The model enables in-depth energy audits and current measurements up to 1,000A without shutting down power at the facility.

True RMS: accurate readings with distorted waveforms

Switching power supplies, dimmers, LED lamps, and inverters distort current and voltage waveforms. Clamp meters without True RMS are designed for pure sine waves and can produce errors in such networks. The Ermenrich Zing DZ60 calculates the true root mean square value and accurately measures AC current and voltage in offices, server rooms, and facilities with LED lighting.

Energy audits and HVAC systems

The 30mm jaw opening and AC/DC current measurement up to 1,000A make it easy to test the main incoming cables, check phase distribution, and verify the operation of high-power UPS systems or solar power plants. The thermocouple (up to +1,000°C) makes this clamp meter indispensable for HVAC specialists. It conveniently monitors compressor temperatures, refrigerant lines, and radiators as well as helps to locate overheated contacts in electrical panels.

High resolution and component-level repair

The 6,000-count display provides excellent measurement resolution. Three-phase network voltage (up to 750V AC and up to 800V DC) is displayed with tenths of a volt without switching to a higher range. The device easily replaces a multimeter for PCB repair. It measures the capacitance of start capacitors (up to 100µF), analyzes PWM signals using the frequency meter (up to 10MHz), and identifies faulty diodes as well as instantly locates open circuits thanks to the sensitive continuity test (< 100Ω).

Reliability in any conditions

The clamp meter operates reliably at temperatures from –10°C to +50°C, making it suitable for use on unheated premises as well as outdoors during transitional seasons. The bright screen backlight is invaluable in dark basements and de-energized rooms. User safety is ensured by the CAT III 600V rating. The device is powered by a single 9V battery (purchased separately), and an auto-off function preserves battery life during prolonged inactivity.

Key features:

  • True RMS ensures accurate AC current and voltage readings with distorted waveforms
  • AC and DC current up to 1,000A simplifies monitoring of incoming cables, server UPS systems, and solar panels
  • 30mm jaw opening allows convenient work with thick power mains without breaking the circuit
  • Voltage up to 750V (AC) and 800V (DC) supports testing single-phase and three-phase networks, UPS systems, inverters, and power supplies
  • 6,000-count display delivers high measurement accuracy, including tenths of a volt in three-phase networks
  • Temperature measurement from –20°C to +1,000°C with a thermocouple helps instantly locate overheated contacts and audit radiators and motors
  • Full electronics toolkit: capacitance, frequency, duty cycle measurement, fast open-circuit detection, and semiconductor testing

The kit includes:

  • Digital clamp meter
  • Probe – 2 pcs.
  • Thermocouple
  • Pouch
  • User manual and warranty card
Brand Ermenrich
Warranty 5 years
EAN 5905555028743
Package size (LxWxH) 22x11x6 cm
Shipping Weight 0.55 kg
Selection of the measuring limit automatic, manual
Basic functions ammeter, capacitance meter, duty cycle meter, frequency meter, ohmmeter, thermocouple, voltmeter
DC voltage measuring limit 600mV: accuracy ±(0.8%+3); 6V/60V/600V: accuracy ±(1.5%+3); 800V: accuracy ±(2.0%+3)
AC voltage measuring limit 600mV: accuracy ±(0.8%+20); 6V/60V/600V: accuracy ±(1.8%+5); 750V: accuracy ±(2.5%+5)
DC current measuring limit 60A: accuracy ±(2.8%+10); 600A: accuracy ±(2.8%+8); 1,000A: accuracy ±(3.0%+5)
AC current measuring limit 60A: accuracy ±(3.0%+10); 600A: accuracy ±(3.0%+8); 1,000A: accuracy ±(3.0%+5)
Resistance measuring limit 600Ω: accuracy ±(1.0%+4); 6kΩ/60kΩ/600kΩ: accuracy ±(1.5%+2); 6MΩ: accuracy ±(2.5%+3); 60MΩ: accuracy ±(3.5%+5)
Capacity measuring limit 40nF: accuracy ±(5.0%+100); 400nF: accuracy ±(3.0%+5); 4µF/40µF: accuracy ±(3.5%+5); 100µF: accuracy ±(5.0%+5)
Frequency measurement limits 10Hz: accuracy ±(1.5%+5); 100Hz/1kHz/10kHz/100kHz/1MHz/10MHz: accuracy ±(1.2%+2)
Duty cycle measurement range 0.5–99.0%: accuracy ±(1.2%+2)
Temperature measurement range –20...+1,000°C: accuracy ±(3%+5°C)
Wire mapping yes
Continuity test +, threshold <100Ω, test current <1mA
Diodes test yes
Diode test +, test current 0.3mA, open-circuit voltage 1.5V DC
True RMS yes
Hold function yes
Limit value function (Min/Max) yes
DCA Zero yes
Input impedance 7.8MΩ (DC and AC)
Throughput capacitance 50/60Hz (AAC/VAC)
Display yes
Display counts 6000
Display backlight yes
Safety standards IEC 61010-1
Overvoltage category CAT III 600V
Operating temperature range, °C -10 — 50
Power supply 9V battery – 1 pc. (not included)
Auto power off yes

Política de devoluções

Temos uma política de devolução de 14 dias. Se não estiver satisfeito com a sua compra, devolva-a na sua embalagem original e certifique-se de que coloca a embalagem original do produto dentro da caixa de envio para evitar quaisquer danos.

Todos os artigos devem estar no seu estado original e não devem ser utilizados. O valor da sua compra será reembolsado. .

As despesas de envio não serão reembolsadas.

Se a devolução se dever a um produto defeituoso, poderá ser compensado pelo envio da devolução.

Se necessitar de efetuar uma devolução, contacte-nos para obter mais informações.

POLÍTICA DE ENVIO

- De 0 a 2 kg - custo de envio: 12,50 euros.

- De 2.001 kg a 30 kg - custo de envio: 17,00 euros.

- A partir de 30,001 kg - custo de envio: 30,00 euros.

Em caso de recolha no nosso armazém ou pontos de revenda - o envio é gratuito.