MAGUS Pol 850 Polarizing Microscope
- €2,958.98
- €2,958.98
- Unit price
- per
Fast Shipping
Most of our order are shipped in 2 working days*
Most of our order are shipped in 2 working days*
We have a 14-day return policy. If you are not satisfied with your purchase, please return it in its original packaging and be sure to put the original product packaging inside the shipping box to avoid any damage. All items must be in their original condition and unused. The value of your purchase will be refunded. Shipping charges will not be refunded.
The microscope is designed to study objects in polarized and natural light.
In the transmitted light you can study geological specimens as well as anisotropic biological and polymeric specimens in thin sections.
In the reflected light – polished sections with one polished side. The thickness of the polished sections is arbitrary usually 5–10mm. The microscope allows you to examine opaque objects up to 15mm thick.
A polarizing microscope uses the birefringence of anisotropic specimen to deliver an image. Plane-polarized light when passing through an anisotropic specimen splits into two beams and changes the plane of polarization. The analyzer brings the vibrations of the beams into the same plane and axis thereby causing destructive and constructive interference to occur between the two wavefronts. The bright high-contrast image changes color when the stage rotates.
This microscope has strain-free objectives. The intermediate tube holds the analyzer and Bertrand lens and it has a slot for compensators. The microscope is used in crystallography petrography mineralogy forensics medicine and other fields of science.
Microscope head
Trinocular head with infinity plan achromatic objectives. Digital image capturing devices are mounted in the trinocular tube. The eyepiece/camera light path selection knob allows you to direct the light beam to either the digital camera or the eyepiece tubes.
The diopter adjustment is on the left tube.
Revolving nosepiece
Five objectives. A free slot is used for centering the light source. An additional objective can also be installed in a free slot in order to achieve extra magnification. The design of the revolving nosepiece (“away from the observer”) frees up space at the front of the stage and therefore the user can see the objective inserted into the optical path. The revolving nosepiece slots are centered to align the optical axis of the objective and microscope.
Objectives
Infinity plan achromatic objectives are designed specifically for polarized light observations: The strain-free optics ensure that the birefringence comes from the specimen and not from the optical elements. The objectives are designed to study samples without cover slips.
Focusing mechanism
Coaxial coarse and fine focusing knobs are located at the bottom of the stand on both sides. The user can place their hands on the table and take a relaxed pose while observing. The focusing adjustment is smooth and effortless.
The design of the focusing mechanism provides for quick microscope adjustment after changing the object of study. For this purpose a coarse focusing lock knob is located on the right side. The coarse tension can be adjusted by turning the ring on the left side.
Stage
The stage rotates 360° to view the color change of the sample when the polarizer and analyzer are in crossed orientation. The stage has a gradation of the rotation angle. With the vernier scale measurements are made with an accuracy of 0.1°.
The stage can be centered with two screws because the analysis of an anisotropic object in polarized light requires the precise alignment of the rotation axis of the stage with the optical axis of the microscope.
Light source
30W halogen bulbs are used in both reflected and transmitted light illuminators. Halogen bulbs emit light with a color temperature that allows for comfortable work. The 30W bulb is bright enough for you to observe with the 4x to 100x magnification objectives that are used for brightfield and polarized light microscopy.
Reflected light illumination
The illumination system makes it possible to set up the Köhler illumination. The field and aperture diaphragms are pre-centered at the factory and require no additional centering. If necessary the diaphragms can be adjusted with centering screws. The light source is centered along three axes. The removable analyzer and polarizer are for the polarization microscopy technique. The polarizer rotates 0–360° the analyzer rotates 360° and the vernier scale on the analyzer provides accurate angle measurement.
A set of filters can help you adjust the color reproduction.
Transmitted light illumination
Köhler illumination: adjustable field diaphragm; centered and height-adjustable Abbe condenser with adjustable aperture diaphragm and swivel auxiliary lens. NA = 1.25. The polarizer is 0–360° rotatable with four rotation angles of 0° 90° 180° 270° marks on the scale. The analyzer rotates 360° the vernier scale on the analyzer provides accurate angle measurement.
Köhler illumination in reflected and transmitted light
The Köhler illumination setup enhances the image quality of a specimen. With such illumination you can achieve maximum resolution on each objective and uniform illumination of the field of view with no darkening at the edges. The object of study is in sharp focus and the image artifacts are removed.
Studying samples in polarized light
The intermediate tube holds the analyzer and Bertrand lens and it has a slot for compensators. The analyzer is inserted into the light path to observe objects in polarized light. When the polarizer and analyzer rotate the polarization angle changes. You can achieve a mutually perpendicular position by setting both filters to the “0” position. When the microscope stand is rotated depending on the polarization angle the surface of the sample reflects light differently. The Bertrand lens is used for conoscopic studies. The compensators are designed to enhance the contrast of samples with weak birefringence.
Accessories
There is a line of accessories designed for the microscope.
Additional objectives can be used for studying objects up to 0.32µm.
Eyepieces extend the magnification range of the microscope. Additional eyepieces will help to utilize the full potential of an objective that is used more often.
A digital camera that outputs the microscope image on a monitor stores files and that has software that takes real-time measurements of specimens. A calibration slide for measuring objects that can be combined with an eyepiece with a scale or the camera software.
Key features:
The kit includes:
Available on request:
Brand | MAGUS |
Warranty years | 5 |
EAN | 5905555018539 |
Package size (LxWxH) cm | 44.7x42.2x67.5 |
Shipping Weight kg | 11.5 |
Head | trinocular |
Head inclination angle | 30 ° |
Eyepiece tube diameter mm | 23.2 |
Objectives | infinity plan achromatic strain-free: PL 5x/0.12; PL 10x/0.25; PL 40x/0.6; PL 60x/0.7 (*optional: PL 2.5x/0.07; PL 50x/0.7; PL 80x/0.8; PL 100x/0.85); parfocal height 45mm designed for studying specimens without cover slips |
Revolving nosepiece | for 5 objectives centering |
Working distance mm | 26.1 (5x); 5.0 (10x); 3.98 (40x); 2.03 (60x); 11 (2.5x); 3.69 (50x); 1.25 (80x); 0.4 (100x) |
Stage mm | Ø150 |
Eyepiece diopter adjustment diopters | ±5 (on the left tube) |
Condenser | Abbe condenser NA 1.25 with an adjustable aperture diaphragm and a swivel lens |
Diaphragm | adjustable aperture diaphragm adjustable iris field diaphragm |
Focus | coaxial coarse focusing (21mm 39.8mm/circle with a lock knob and tension adjusting knob) and fine focusing (0.002mm) |
Brightness adjustment | yes |
Light source type | reflected and transmitted light: 12V/30W |
Operating temperature range °C | 5 — 35 |
Assembly and installation difficulty level | complicated |
Type | biological light/optical |
Nozzle | Siedentopf |
Magnification x | 50–600 basic configuration (*optional: 25–1000/1600/2000) |
Eyepieces | 10х/20; 10x/20 with a scale (*optional: 16x/11; 20х/11) |
Stage features | 360 ° rotatable centering 1° graduation of the rotation angle; a vernier scale for measuring angles with an accuracy of 0.1° |
Illumination | halogen |
Power supply | 220±22V 50Hz AC network |
Light filters | reflected light: matt yellow green blue |
User level | experienced users professionals |
Polarizer | transmitted light: with 0° 90° 180° 270° marks on the scale; 360° rotatable; reflected light: removable |
Intermediate tube | built-in analyzer with rotation 0–360°; a vernier scale for measuring angles with an accuracy of 0.1°; Bertrand lens; slot for installing compensators |
Compensator | λ compensator; λ/4 compensator; quartz wedge |
Application | laboratory/medical |
Illumination location | dual |
Research method | bright field polarization |
Pouch/case/bag in set | dust cover |
We have a 14-day return policy. If you are not satisfied with your purchase, please return it in its original packaging and be sure to put the original product packaging inside the shipping box to avoid any damage..
All items must be in their original condition and unused. The value of your purchase will be refunded. .
Shipping charges will not be refunded.
If the return is due to a defective product, you may be compensated for the return shipping.
Please contact us for more details if you need to make a return..
- From 0 to 2 kg - shipping cost: 12,50 euros.
- From 2.001 kg to 30 kg - shipping cost: 17,00 euros.
- From 30,001 kg - shipping cost: 30,00 euros.
In case of collection at our warehouse or resale points - the shipping is free.
Thanks for subscribing!
This email has been registered!