{"product_id":"ermenrich-zing-dz120-digital-clamp-meter","title":"Ermenrich Zing DZ120 Digital Clamp Meter","description":"\u003cp\u003eThe Ermenrich Zing DZ120 is a professional digital clamp meter with a built-in wattmeter. The device automatically calculates load power in AC and DC circuits, so you don’t need to separately measure current and voltage and then multiply them. The clamp meter is suitable for facility power engineers and electrical equipment commissioning and maintenance specialists. It can also be used for selective measurements during energy audits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent up to 1,500A and 52mm jaw opening\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe jaws accommodate large-diameter cables, busbars, and bundles of parallel conductors. Both AC and DC current can be measured, which is important for solar installations, battery systems, and electric vehicles. Clamp only one phase or pole conductor at a time. The Inrush function captures short-term inrush current surges, for example, when diagnosing powerful electric motors and transformers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy with distorted waveforms\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eModern loads often draw non-sinusoidal current: This is how variable frequency drives, LED drivers, switching power supplies, and inverters operate. True RMS technology takes the waveform into account. Therefore, the current and power in such circuits are not underestimated. The built-in frequency meter up to 40MHz and duty cycle meter help to check the frequency at which the drive is operating at the moment of measurement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMultimeter functions in one device\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe capabilities of the Ermenrich Zing DZ120 cover the function set of most professional multimeters. With the thermocouple, the clamp meter measures temperature from −100°C to +1,000°C. You can check the heating of contacts and windings under load or the temperature in freezers. The device also measures capacitance up to 40mF, resistance up to 40MΩ, tests diodes with voltage up to 2.8V, and checks for open or short circuits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety and kit\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe device complies with CAT IV 600V and CAT III 1,000V overvoltage categories. The NCV indicator helps to pre-locate a phase but the absence of voltage before work must be confirmed by a contact measurement. The backlit display is easy to read in poorly lit rooms. Power is supplied by a single 9V battery (not included); the auto-off function preserves battery life during prolonged inactivity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBuilt-in wattmeter up to 900kW automatically calculates load power, saving time on manual calculations during energy audits\u003c\/li\u003e\n\u003cli\u003e52mm jaw opening and currents up to 1,500A allow testing main cables and busbars without shutting off power\u003c\/li\u003e\n\u003cli\u003eInrush function: captures inrush currents when starting electric motors and power equipment\u003c\/li\u003e\n\u003cli\u003eTrue RMS technology guarantees accurate measurements in circuits with switching power supplies, inverters, and variable frequency drives\u003c\/li\u003e\n\u003cli\u003eThermocouple with measurement from −100°C to +1,000°C is suitable for monitoring cryogenic systems and red-hot furnaces or contacts under load\u003c\/li\u003e\n\u003cli\u003eCapacitance (up to 40mF) and frequency (up to 40MHz) cover all needs for the in-depth diagnostics of PCBs, inverters, and digital circuits\u003c\/li\u003e\n\u003cli\u003eNCV detector and CAT IV 600V\/CAT III 1,000V ratings ensure safety when locating phases, working in electrical rooms and at the electrical installation's incoming point\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eThe kit includes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDigital clamp meter\u003c\/li\u003e\n\u003cli\u003eProbe – 2 pcs.\u003c\/li\u003e\n\u003cli\u003eThermocouple\u003c\/li\u003e\n\u003cli\u003ePouch\u003c\/li\u003e\n\u003cli\u003eUser manual and warranty card\u003c\/li\u003e\n\u003c\/ul\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eErmenrich\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e5905555028774\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage size (LxWxH)\u003c\/td\u003e\n\u003ctd\u003e32x16x6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e0.88 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelection of the measuring limit\u003c\/td\u003e\n\u003ctd\u003eautomatic, manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBasic functions \u003c\/td\u003e\n\u003ctd\u003eammeter, capacitance meter, duty cycle meter, frequency meter, ohmmeter, thermocouple, voltmeter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC voltage measuring limit\u003c\/td\u003e\n\u003ctd\u003e400mV: accuracy ±(0.1%+5); 4V\/40V\/400V: accuracy ±(0.1%+4); 1,000V: accuracy ±(0.5%+4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC voltage measuring limit\u003c\/td\u003e\n\u003ctd\u003e400mV: accuracy ±(0.8%+40); 4V\/40V\/400V\/750V: accuracy ±(1.0%+30)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC current measuring limit\u003c\/td\u003e\n\u003ctd\u003e400A: accuracy ±(2.0%+30); 1,500A: accuracy ±(2.5%+30)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC current measuring limit\u003c\/td\u003e\n\u003ctd\u003e400A: accuracy ±(2.8%+30); 1,500A: accuracy ±(2.5%+30)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance measuring limit\u003c\/td\u003e\n\u003ctd\u003e400Ω: accuracy ±(0.5%+9); 4kΩ\/40kΩ\/400kΩ: accuracy ±(1.0%+4); 4MΩ: accuracy ±(2.0%+10); 40MΩ: accuracy ±(3.0%+10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacity measuring limit\u003c\/td\u003e\n\u003ctd\u003e400nF: accuracy ±(3.5%+40); 4µF\/40µF\/400µF: accuracy ±(3.5%+10); 4mF\/20mF: accuracy ±(5.0%+10); 40mF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency measurement limits\u003c\/td\u003e\n\u003ctd\u003e40Hz\/400Hz\/4kHz\/40kHz\/400kHz\/4MHz\/40MHz: accuracy ±(0.3%+2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC power measurement limits\u003c\/td\u003e\n\u003ctd\u003e900kW: accuracy ±(3%+10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC power measurement limits\u003c\/td\u003e\n\u003ctd\u003e900kW: accuracy ±(2.8%+10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDuty cycle measurement range\u003c\/td\u003e\n\u003ctd\u003e10%–95.0%: accuracy ±(1.0%+2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature measurement range\u003c\/td\u003e\n\u003ctd\u003e–100°C...+1,000°C: accuracy ±(1.0%+2.5°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire mapping\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity test\u003c\/td\u003e\n\u003ctd\u003e+, threshold \u0026lt;50Ω, test current \u0026lt;0.5mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiodes test\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiode test\u003c\/td\u003e\n\u003ctd\u003e+, test current 0.3mA, open-circuit voltage 2.8V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-contact voltage detection (NCV)\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrue RMS \u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHold function\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLimit value function (Min\/Max)\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDCA Zero\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush current measurement (INRUSH)\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput impedance\u003c\/td\u003e\n\u003ctd\u003e10MΩ (DC and AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThroughput capacitance\u003c\/td\u003e\n\u003ctd\u003e50–400Hz (AAC\/VAC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrest factor (peak factor)\u003c\/td\u003e\n\u003ctd\u003e3.0 on 40A and 400A ranges; 1.4 on 1,000A range (50\/60Hz, 5%–100% of range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay counts\u003c\/td\u003e\n\u003ctd\u003e4000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay backlight\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety standards\u003c\/td\u003e\n\u003ctd\u003eIEC1010-1 (2001); EN61010-1 (2001)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage category\u003c\/td\u003e\n\u003ctd\u003ecat. III (1000V), cat. IV (600V), pollution degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature range, °C\u003c\/td\u003e\n\u003ctd\u003e5 — 40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e9V battery – 1 pc. (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto power off\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Ermenrich","offers":[{"title":"Default title","offer_id":55934990549321,"sku":"87510","price":199.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0426\/8032\/0154\/files\/87510_ermenrich-zing-dz120-digital-clamp-meter_00.jpg?v=1794588714","url":"https:\/\/madeiraoptics.com\/pt-es\/products\/ermenrich-zing-dz120-digital-clamp-meter","provider":"Madeira Optics","version":"1.0","type":"link"}