{"product_id":"ermenrich-zing-dz100-digital-clamp-meter","title":"Ermenrich Zing DZ100 Digital Clamp Meter","description":"\u003cp\u003eThe Ermenrich Zing DZ100 is a professional digital clamp meter for servicing industrial electrical equipment, power installations, and electronics. The jaws open to 52mm, making it easy to clamp around large-diameter main cables, paired conductors, and massive current-carrying busbars in distribution substations. The current is measured without breaking the circuit or shutting down equipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh currents and DC voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe clamp meter measures AC and DC current up to 1,500A, making it suitable for servicing powerful electric motors, generators, UPS systems, battery systems, and welding equipment as well as the power section of EV charging stations. The Inrush function captures short-term inrush current surges when equipment is turned on, which is important for diagnosing loads with high starting torque. DC voltage is measured up to 1,000V, and AC voltage up to 750V. True RMS technology provides accurate readings with non-sinusoidal current waveforms, such as in circuits with inverters, variable frequency drives, and switching power supplies.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCryogenics and thermal monitoring\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe temperature capabilities of this model go far beyond standard testers. The included thermocouple can measure extreme cold down to −100°C. This allows the clamp meter to be used for servicing cryogenic systems, liquefied gas storage facilities, and deep-freeze chambers. The upper limit of +1,000°C easily covers all the requirements for monitoring the heating of metallurgical furnaces, industrial boilers, and heavy equipment exhaust systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectronic component diagnostics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe frequency meter up to 40MHz and duty cycle meter help test generators, PWM controllers, and digital circuits. The capacitance meter up to 40mF tests both small capacitors and large electrolytic ones in power supplies, inverters, and welding machines. In diode test mode, the device outputs up to 2.8V, which is sufficient to test diodes, transistor junctions, and high-power white and blue LEDs in TV backlights or car headlights.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety and convenience\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor safe operation in high-voltage areas, a non-contact voltage detection (NCV) function is provided. It helps locate live wires or hidden wiring at a distance. The device complies with CAT IV 600V and CAT III 1,000V overvoltage categories. The audible continuity test with a threshold below 50Ω quickly finds open and short circuits. All the data is displayed in a large format on a screen with a bright backlight, which is invaluable when inspecting dark workshops or de-energized rooms. The device is powered by a single 9V battery (not included).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e52mm jaw opening clamps around thick power cables and bundles of parallel conductors of a single phase\u003c\/li\u003e\n\u003cli\u003eAC and DC current up to 1,500A enables the auditing of traction substations and EV charging stations\u003c\/li\u003e\n\u003cli\u003eInrush function measures peak inrush currents when starting motors and powerful loads\u003c\/li\u003e\n\u003cli\u003eTrue RMS ensures accurate readings with non-sinusoidal current from inverters, variable frequency drives, and switching power supplies \u003c\/li\u003e\n\u003cli\u003eDC voltage up to 1,000V and AC voltage up to 750V: ideal for electrical systems, UPS systems, battery systems, and solar installations\u003c\/li\u003e\n\u003cli\u003eTemperatures from −100°C to +1,000°C (with thermocouple) support monitoring the heating of contacts, motors, boilers, and refrigeration equipment operation \u003c\/li\u003e\n\u003cli\u003eFrequency meter up to 40MHz and capacitance up to 40mF provide in-depth diagnostics of digital circuits and high-power inverters \u003c\/li\u003e\n\u003cli\u003eDiode test with 2.8V allows testing high-power indicator and lighting LEDs\u003c\/li\u003e\n\u003cli\u003eAudible continuity test, non-contact voltage detector (NCV), CAT IV 600V\/CAT III 1,000V protection rating\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eThe kit includes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDigital clamp meter\u003c\/li\u003e\n\u003cli\u003eProbe – 2 pcs.\u003c\/li\u003e\n\u003cli\u003eThermocouple\u003c\/li\u003e\n\u003cli\u003ePouch\u003c\/li\u003e\n\u003cli\u003eUser manual and warranty card\u003c\/li\u003e\n\u003c\/ul\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eErmenrich\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e5905555028767\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage size (LxWxH)\u003c\/td\u003e\n\u003ctd\u003e32x16x6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e0.88 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelection of the measuring limit\u003c\/td\u003e\n\u003ctd\u003eautomatic, manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBasic functions \u003c\/td\u003e\n\u003ctd\u003eammeter, capacitance meter, duty cycle meter, frequency meter, ohmmeter, thermocouple, voltmeter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC voltage measuring limit\u003c\/td\u003e\n\u003ctd\u003e400mV: accuracy ±(0.1%+5); 4V\/40V\/400V: accuracy ±(0.1%+4); 1,000V: accuracy ±(0.5%+4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC voltage measuring limit\u003c\/td\u003e\n\u003ctd\u003e400mV: accuracy ±(0.8%+40); 4V\/40V\/400V\/750V: accuracy ±(1.0%+30)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC current measuring limit\u003c\/td\u003e\n\u003ctd\u003e400A: accuracy ±(2.0%+30); 1,500A: accuracy ±(2.5%+30)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC current measuring limit\u003c\/td\u003e\n\u003ctd\u003e400A: accuracy ±(2.8%+30); 1,500A: accuracy ±(2.5%+30)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance measuring limit\u003c\/td\u003e\n\u003ctd\u003e400Ω: accuracy ±(0.5%+9); 4kΩ\/40kΩ\/400kΩ: accuracy ±(1.0%+4); 4MΩ: accuracy ±(2.0%+10); 40MΩ: accuracy ±(3.0%+10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacity measuring limit\u003c\/td\u003e\n\u003ctd\u003e400nF: accuracy ±(3.5%+40); 4µF\/40µF\/400µF: accuracy ±(3.5%+10); 4mF\/20mF: accuracy ±(5.0%+10); 40mF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency measurement limits\u003c\/td\u003e\n\u003ctd\u003e40Hz\/400Hz\/4kHz\/40kHz\/400kHz\/4MHz\/40MHz: accuracy ±(0.3%+2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDuty cycle measurement range\u003c\/td\u003e\n\u003ctd\u003e10%–95.0%: accuracy ±(1.0%+2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature measurement range\u003c\/td\u003e\n\u003ctd\u003e–100°C...+1,000°C: accuracy ±(1.0%+2.5°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire mapping\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity test\u003c\/td\u003e\n\u003ctd\u003e+, threshold \u0026lt;50Ω, test current \u0026lt;0.5mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiodes test\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiode test\u003c\/td\u003e\n\u003ctd\u003e+, test current 0.3mA, open-circuit voltage 2.8V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-contact voltage detection (NCV)\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrue RMS \u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHold function\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLimit value function (Min\/Max)\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDCA Zero\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush current measurement (INRUSH)\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput impedance\u003c\/td\u003e\n\u003ctd\u003e10MΩ (DC and AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThroughput capacitance\u003c\/td\u003e\n\u003ctd\u003e50–400Hz (AAC\/VAC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrest factor (peak factor)\u003c\/td\u003e\n\u003ctd\u003e3.0 on 40A and 400A ranges; 1.4 on 1,000A range (50\/60Hz, 5%–100% of range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay counts\u003c\/td\u003e\n\u003ctd\u003e4000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay backlight\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety standards\u003c\/td\u003e\n\u003ctd\u003eIEC1010-1 (2001); EN61010-1 (2001)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage category\u003c\/td\u003e\n\u003ctd\u003ecat. III (1000V), cat. IV (600V), pollution degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature range, °C\u003c\/td\u003e\n\u003ctd\u003e5 — 40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e9V battery – 1 pc. (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto power off\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Ermenrich","offers":[{"title":"Default title","offer_id":55934990418249,"sku":"87509","price":179.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0426\/8032\/0154\/files\/87509_ermenrich-zing-dz100-digital-clamp-meter_00.jpg?v=1794588710","url":"https:\/\/madeiraoptics.com\/products\/ermenrich-zing-dz100-digital-clamp-meter","provider":"Madeira Optics","version":"1.0","type":"link"}