{"product_id":"ermenrich-zing-dz40-digital-clamp-meter","title":"Ermenrich Zing DZ40 Digital Clamp Meter","description":"\u003cp\u003eThe Ermenrich Zing DZ40 is a versatile measuring tool for power engineers, instrumentation and control (I\u0026amp;C) technicians, and industrial maintenance professionals. The heavy-duty magnetic core with a 30mm jaw opening safely accommodates thick power cables, allowing for the testing of high-load mains without interrupting production processes or breaking the circuit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-current measurement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe key feature of the Ermenrich Zing DZ40 is its ability to measure AC and DC currents up to 1,000A. The device is ideal for inspecting electrical panels, evaluating the power consumption of industrial machinery, welding stations, and heavy-duty electric motors. DC current measurement is indispensable for monitoring industrial UPS systems and large battery banks. The 600V voltage limit fully covers the requirements for monitoring 230\/400V three-phase networks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature measurement and operating conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe device measures temperatures ranging from –20°C to +1,000°C using a thermocouple. This is essential for auditing drying chambers, boiler plants, industrial furnaces, and internal combustion engine (ICE) exhaust systems. The clamp meter is built for harsh environments, operating reliably at ambient temperatures from –10°C to +50°C. This allows for measurements in unheated workshops, hangars, or outdoors during transitional seasons.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency analysis and component testing\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDespite its heavy-duty focus, the device handles electronic component diagnostics with ease. It can measure frequencies up to 10MHz and pulse duty cycles, which is useful for verifying control and PWM signals. The capacitance measurement mode (up to 100µF) helps test capacitors and identify dried-out components. An audible buzzer, which triggers at resistances below 100Ω, is provided for locating open circuits. Moreover, the semiconductor test function, featuring an open-circuit voltage of 1.5V, is ideal for testing rectifier bridges and power diodes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReliability and safety standards\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe tool complies with the CAT III 600V overvoltage category, making it suitable for working in electrical panels and with fixed building wiring. Readings are displayed on a 4,000-count screen with a bright backlight that is invaluable when working in poorly lit electrical rooms and workshops. The device is powered by a single 9V battery (not included), and an auto-off function shuts down the meter after prolonged inactivity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAC and DC current measurement up to 1,000A is suitable for diagnosing energy-intensive installations\u003c\/li\u003e\n\u003cli\u003e30mm jaw opening accommodates thick cables and busbars\u003c\/li\u003e\n\u003cli\u003eTemperature monitoring up to +1,000°C; use the thermocouple to audit furnaces, boilers, and engines\u003c\/li\u003e\n\u003cli\u003eFrequency measurement up to 10MHz is useful for configuring control signals\u003c\/li\u003e\n\u003cli\u003eCAT III 600V overvoltage category ensures safe operation in electrical panels\u003c\/li\u003e\n\u003cli\u003eWide operating temperature range (–10°C to +50°C) provides accurate measurements outdoors and in harsh environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eThe kit includes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDigital clamp meter\u003c\/li\u003e\n\u003cli\u003eProbe – 2 pcs.\u003c\/li\u003e\n\u003cli\u003eThermocouple\u003c\/li\u003e\n\u003cli\u003ePouch\u003c\/li\u003e\n\u003cli\u003eUser manual and warranty card\u003c\/li\u003e\n\u003c\/ul\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eErmenrich\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e5905555028705\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage size (LxWxH)\u003c\/td\u003e\n\u003ctd\u003e24x14x6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e0.71 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelection of the measuring limit\u003c\/td\u003e\n\u003ctd\u003eautomatic, manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBasic functions \u003c\/td\u003e\n\u003ctd\u003eammeter, capacitance meter, duty cycle meter, frequency meter, ohmmeter, thermocouple, voltmeter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC voltage measuring limit\u003c\/td\u003e\n\u003ctd\u003e400mV: accuracy ±(0.8%+3); 4V\/40V\/400V: accuracy ±(1.5%+3); 600V: accuracy ±(2.0%+3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC voltage measuring limit\u003c\/td\u003e\n\u003ctd\u003e400mV: accuracy ±(0.8%+20); 4V\/40V\/400V: accuracy ±(1.8%+5); 600V: accuracy ±(1.0%+4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC current measuring limit\u003c\/td\u003e\n\u003ctd\u003e40A: accuracy ±(2.8%+10); 400A: accuracy ±(2.8%+5); 1,000A: accuracy ±(3.0%+5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC current measuring limit\u003c\/td\u003e\n\u003ctd\u003e40A: accuracy ±(3.0%+10); 400A: accuracy ±(3.0%+5); 1,000A: accuracy ±(3.0%+5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance measuring limit\u003c\/td\u003e\n\u003ctd\u003e400Ω: accuracy ±(1.0%+4); 4kΩ\/40kΩ\/400kΩ: accuracy ±(1.5%+2); 4MΩ: accuracy ±(2.5%+3); 40MΩ: accuracy ±(3.5%+5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacity measuring limit\u003c\/td\u003e\n\u003ctd\u003e40nF: accuracy ±(5.0%+100); 400nF: accuracy ±(3.0%+5); 4µF\/40µF: accuracy ±(3.5%+5); 100µF: accuracy ±(5.0%+5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency measurement limits\u003c\/td\u003e\n\u003ctd\u003e5Hz\/50Hz\/500Hz\/5kHz\/50kHz\/500kHz\/10MHz: accuracy ±(1.2%+2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDuty cycle measurement range\u003c\/td\u003e\n\u003ctd\u003e0.5–99.0%: accuracy ±(1.2%+2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature measurement range\u003c\/td\u003e\n\u003ctd\u003e–20...+1,000°C: accuracy ±(3%+5°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire mapping\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity test\u003c\/td\u003e\n\u003ctd\u003e+, threshold \u0026lt;100Ω, test current \u0026lt;1mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiodes test\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiode test\u003c\/td\u003e\n\u003ctd\u003e+, test current 0.3mA, open-circuit voltage 1.5V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHold function\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDCA Zero\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput impedance\u003c\/td\u003e\n\u003ctd\u003e7.8MΩ (DC and AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThroughput capacitance\u003c\/td\u003e\n\u003ctd\u003e50\/60Hz (AAC\/VAC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay counts\u003c\/td\u003e\n\u003ctd\u003e4000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay backlight\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety standards\u003c\/td\u003e\n\u003ctd\u003eEN 61010-1:2010+A1:2019; EN IEC 61010-2-032:2021+A11:2021\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage category\u003c\/td\u003e\n\u003ctd\u003eCAT III 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature range, °C\u003c\/td\u003e\n\u003ctd\u003e-10 — 50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e9V battery (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto power off\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Ermenrich","offers":[{"title":"Default title","offer_id":55934989271369,"sku":"87503","price":94.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0426\/8032\/0154\/files\/87503_ermenrich-zing-dz40-digital-clamp-meter_00.jpg?v=1794588692","url":"https:\/\/madeiraoptics.com\/es\/products\/ermenrich-zing-dz40-digital-clamp-meter","provider":"Madeira Optics","version":"1.0","type":"link"}