{"product_id":"magus-lum-d470l-fluorescence-digital-microscope","title":"MAGUS Lum D470L Fluorescence Digital Microscope","description":"\u003cp\u003eA research-grade microscope for studying specimens in reflected light using fluorescence and in transmitted light using brightfield. The installation of optional accessories allows for darkfield, phase contrast, differential interference contrast, and polarization microscopy.\nThe coded revolving nosepiece transmits information on the selected objective to the control system. Based on this data, the microscope automatically adjusts the user-defined illumination brightness for each objective. The intelligent lighting control system further enhances operator comfort and eliminates the need for manual adjustment when changing magnification.\nFluorescence microscopy is based on the ability of some substances to glow when exposed to light of a certain part of the spectrum. The reflected light illuminator contains three filter cubes that provide optimal conditions for exciting fluorescence in the commonly used fluorochromes DAPI, FITC, and TRITC as well as their spectral analogs.\nThe microscope is equipped with a 1.7MP camera with a USB 3.0 interface. The camera connects to a computer and displays the image on its screen. The software complements the system with analysis and documentation functions.\nThe microscope is used in medical institutions and laboratories, research organizations, forensic centers, industrial and environmental organizations, pharmaceutical companies, and educational institutions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDigital camera\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe MAGUS CLM50 digital camera is designed for use in fluorescence and darkfield microscopy techniques. The large 9x9µm pixels provide high light sensitivity, which is especially important when working with weak fluorescence signals.\nThe camera is equipped with a 1.7MP sensor producing a realistic image in 1600x1100px.\nVideo is recorded at 33fps at maximum resolution. Videos are smooth, with soft and subtle transitions between frames. The movement of the sample is displayed in real time with no delays. The camera provides convenient work with moving objects and is suitable for conducting demonstrations in a classroom.\nThe camera is equipped with a USB 3.0 interface. The data transfer rate is 10 times faster than that of USB 2.0 cameras. The high-speed camera is recommended for professional laboratories, research, or university training.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMicroscope head\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTrinocular head with infinity-corrected optics. The eyepiece tubes are raised and lowered, changing their position by rotating around the axis. The user can adjust the eyepiece height to suit their individual stature. \nThe digital camera is mounted in the trinocular tube. Fixed beam splitting ratio: 50\/50.\nThe vertical tube has a magnification of 0.55x. The included C-mount adapter does not change the image scale (1x). Therefore, the image is transmitted to the camera sensor with a magnification of 0.55x. When calculating the field of view and on-screen magnification for each objective, use a total factor of 0.55x.\nThe basic configuration includes 10x\/22mm eyepieces with diopter adjustment and high eyepoint for working with glasses.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRevolving nosepiece\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe coded revolver for five objectives is oriented toward the interior: The user can see the objective inserted into the optical path, and the space above the stage is free. Above the nosepiece is a slot with a plug for installing an analyzer, compensators, or differential interference contrast sliders.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlan semi-apochromatic fluorescence objectives\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe objective lenses are made of fluorite, a mineral with a high degree of transparency over a wide wavelength spectrum, without autofluorescence and birefringence, with corrected secondary spectrum. The high numerical aperture enhances the objective's resolving power. The image in the eyepieces and through the digital camera is cleaner, has more contrast, and is brighter than with regular plan achromatic objectives.\nPlan semi-apochromatic objectives have chromatic aberrations that are corrected for four colors, spherical aberration corrected for three colors, and field curvature corrected for 90% of the field of view diameter.\nThe 4x objective is designed to work with specimens with or without a coverslip. The 10x, 20x, 40x, and 100x objectives are used to observe specimens with a 0.17mm coverslip. The 100x objective supports oil immersion. All of the objectives are designed for the infinity-corrected tube length. The parfocal distance is 60mm.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaintaining a comfortable brightness level in transmitted light when changing magnifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe objectives of different magnifications transmit light with different levels of intensity, and so each time you change objectives, the brightness of the light must be adjusted. Switching from a higher to a lower magnification objective causes eye fatigue due to a sharp increase in the brightness of the eyepiece image. The MAGUS Lum D470L, which is equipped with intelligent brightness control, solves this problem. The optimal level of light brightness is automatically switched for each objective, thereby eliminating unexpected changes in brightness when changing magnification. This feature optimizes the workflow, reduces eye fatigue, and improves comfort during extended use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFocusing mechanism\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWith a large number of specimens, the operator constantly uses the fine focusing knob for performing their work. To reduce wrist strain, the microscope uses a responsive mechanism with smooth travel. The fine focusing knob has special grooves for your fingers. Fine focus adjustment is effortless, which reduces hand strain during long work sessions.\nThe microscope features low-position coaxial coarse and fine focusing knobs. The researcher can place their hands on the table and take a comfortable position in front of the microscope.\nThe coarse focus lock knob helps you quickly adjust the microscope after changing the object of study. The knob is located on the left side of the microscope on the same axis as the focusing mechanism.\nThe ring on the right side adjusts the tension of the coarse focusing travel. The user adjusts the comfortable tension for work.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStage\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe stage does not have an X-axis rack and pinion, which improves convenience. The belt-driven mechanism allows for smooth movement of the specimen. The specimen holder is secured with two screws and can be easily removed during manual scanning.\nThe long stage control handle ensures user comfort: The hand rests on the table with no strain.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEpi-fluorescence illuminator\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eInside the attachment body, there is a 4-position rotating turret with three narrowband fluorescence filters for the fluorochromes DAPI, FITC, and TRITC as well as their spectral analogs. The filter is selected by rotating the ring. One position of the turret corresponds to the brightfield observations.\nA field diaphragm and an aperture diaphragm enable Köhler illumination in reflected light.\nThe excitation light sources are LEDs. The LEDs instantly reach the brightness that is set by the user. They do not heat up during prolonged use and can switch off quickly, if necessary. This makes it easy to switch from the brightfield technique to fluorescence and back again. The LED lifetime is 50,000 hours. It is recommended to choose LED-based fluorescence for higher education as it is the safest option and requires minimal maintenance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCondenser\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Abbe condenser is height-adjustable and can be centered. Mounting type: dovetail.\nThe condenser ring adjusts the iris aperture diaphragm. The condenser body has an aperture marking, and the ring has an indicator marker. To achieve a high-contrast image, it is recommended to set the aperture diaphragm slightly below the numerical aperture of the objective in use by using the markings and indicator as a guide.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTransmitted light source\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe transmitted light illuminator uses a 3W LED. The microscope illuminator has the function of adjusting the color temperature in the range of 3000K to 7000K. The user selects a comfortable color temperature and can easily switch it with one button whenever specimen examination requires an illumination adjustment. \nThe LED lifetime is 50,000 hours.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKöhler illumination in transmitted light\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe light source is located at the rear of the microscope base and is directed to the collector via a mirror. The image contrast is controlled by the condenser aperture diaphragm, while the illuminated field area is adjusted by the field diaphragm. \nKöhler illumination provides even illumination of the field of view, reduces stray light, and allows the objective to achieve its maximum resolution.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStatus LCD screen\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe LCD screen on the base of the microscope displays the objective magnification, brightness and color temperature of the light source, and operating mode (“sleep” and “eco”).\nThe functions are controlled using the LCD screen and a multifunctional knob. The user adjusts the brightness and color temperature of the illumination, locks the brightness adjustment, and then sets the sleep mode and auto-off timers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eErgonomic design\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePhysical discomfort causes fatigue and reduces productivity. The ergonomic design of the microscope plays an important role in everyday scientific research. \nMAGUS Lum D470L provides user comfort during operation.\nThe user can adjust the viewing height by changing the position of the eyepiece tubes, reducing strain on the back and neck.\nFocusing knobs are located at the bottom of the body. The user does not need to strain their hands. Thanks to the smooth movement of the mechanism, the user can effortlessly focus on the object. \nThe microscope is operated with minimal hand movement, since the long stage control handle and fine focusing knob are located in the same working area.\nThe microscope is equipped with a special carrying handle.\nThe design for the hidden placement of the power adapter and power cord improves the workplace esthetic and safety of carrying the microscope as well as simplifies storage of the device.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAccessories\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThere is a line of accessories designed specifically for this microscope.\nOptional objectives provide additional magnification.\nEyepieces extend the magnification range of the microscope. Optional eyepieces help you maximize the potential of the objective that you use most often.\nThe optional attachments for phase contrast, darkfield, polarization, and DIC expand the range of microscopy techniques, allowing you to study specimens that are invisible in brightfield.\nA calibration slide is used to measure objects and can be combined with the eyepiece with a scale or with the camera software.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlternative models\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMAGUS Lum D470L can be considered as an alternative to the following models: Carl Zeiss Axiolab 5, Leica DM 2000, Leica DM 2000LED, Nikon ECLIPSE Si, Olympus BX 43, Olympus BX 46. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMicroscope features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eStudy of specimens emitting fluorescence when exposed to excitation light\u003c\/li\u003e\n\u003cli\u003eMicroscopy techniques: fluorescence in reflected light, brightfield in transmitted light\u003c\/li\u003e\n\u003cli\u003eThe trinocular head with a vertical tube for installing a digital camera and height adjustment to adjust to the observer; light beam splitting 50\/50\u003c\/li\u003e\n\u003cli\u003eCoded revolving nosepiece: The brightness of the light source is set automatically depending on the selected objective\u003c\/li\u003e\n\u003cli\u003ePlan semi-apochromatic fluorescence objectives with high resolving power\u003c\/li\u003e\n\u003cli\u003eTransmitted light illuminator: energy-saving 3W LED with a lifetime of up to 50,000 hours\u003c\/li\u003e\n\u003cli\u003eKöhler illumination and a centered and height-adjustable condenser with objective aperture markings\u003c\/li\u003e\n\u003cli\u003eSmart transmitted light control system: automatic brightness selection, brightness adjustment lock, auto-off timer, LCD operating status screen\u003c\/li\u003e\n\u003cli\u003eStage without an X-axis positioning rack and with a long control handle for convenient operation\u003c\/li\u003e\n\u003cli\u003eErgonomic stand with carrying handle and the hidden placement of the power cord and power adapter\u003c\/li\u003e\n\u003cli\u003eWide range of compatible optional accessories\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCamera features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFor fluorescence and darkfield observations\u003c\/li\u003e\n\u003cli\u003e1.7MP resolution is optimal for working with high-magnification objectives; the large 9x9µm pixels provide high light sensitivity and a low noise level\u003c\/li\u003e\n\u003cli\u003e33fps for observing moving objects, recording video, and moving the sample without jerking or delays\u003c\/li\u003e\n\u003cli\u003ePeltier element reduces the sensor temperature during prolonged operation and eliminates thermal noise. Therefore, long shutter speeds can be used when taking photos\u003c\/li\u003e\n\u003cli\u003eGlobal shutter for fast signal readout from the sensor, increased image brightness, and no false optical effects when observing moving objects\u003c\/li\u003e\n\u003cli\u003eSONY Exmor color CMOS backlit sensor provides a low noise level and high light sensitivity even in low-light conditions. You will get clearer, brighter, and more color-saturated images\u003c\/li\u003e\n\u003cli\u003eUSB 3.0 interface for fast data transfer with no jerking or lagging\u003c\/li\u003e\n\u003cli\u003eSoftware with functions for taking photos, recording video, editing, displaying images on an external screen, and measuring linear and angular dimensions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePackage:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMAGUS CLM50 digital camera (digital camera, USB cable, power adapter, carrying case, USB flash drive with drivers and software, user manual, and warranty card)\u003c\/li\u003e\n\u003cli\u003eStand with transmitted light source, focusing mechanism, LCD screen, and revolving nosepiece\u003c\/li\u003e\n\u003cli\u003eStage holder with a condenser mount\u003c\/li\u003e\n\u003cli\u003eStage with specimen holder\u003c\/li\u003e\n\u003cli\u003eAbbe condenser\u003c\/li\u003e\n\u003cli\u003eEpi-fluorescence illuminator\u003c\/li\u003e\n\u003cli\u003eFITC\/TRITC\/DAPI fluorescence filter cubes\u003c\/li\u003e\n\u003cli\u003eLamphouse with LEDs\u003c\/li\u003e\n\u003cli\u003eTrinocular microscope head\u003c\/li\u003e\n\u003cli\u003ePlan semi-apochromatic fluorescence objective PlanF S-Apo 4x\/0.13 ∞\/– WD 17mm, parfocal distance: 60mm\u003c\/li\u003e\n\u003cli\u003ePlan semi-apochromatic fluorescence objective PlanF S-Apo 10x\/0.30 ∞\/0.17 WD 16mm, parfocal distance: 60mm\u003c\/li\u003e\n\u003cli\u003ePlan semi-apochromatic fluorescence objective PlanF S-Apo 20x\/0.50 ∞\/0.17 WD 2.7mm, parfocal distance: 60mm\u003c\/li\u003e\n\u003cli\u003ePlan semi-apochromatic fluorescence objective PlanF S-Apo 40x\/0.75 ∞\/0.17 WD 1.4mm, parfocal distance: 60mm\u003c\/li\u003e\n\u003cli\u003ePlan semi-apochromatic fluorescence objective PlanF S-Apo 100x\/1.40 oil ∞\/0.17 WD 0.18mm, parfocal distance: 60mm\u003c\/li\u003e\n\u003cli\u003e10x\/22mm eyepiece with high eyepoint and diopter adjustment (2 pcs.)\u003c\/li\u003e\n\u003cli\u003eEyecup (2 pcs.)\u003c\/li\u003e\n\u003cli\u003eC-mount adapter\u003c\/li\u003e\n\u003cli\u003eMicroscope power adapter and power cord\u003c\/li\u003e\n\u003cli\u003ePower supply for a fluorescence attachment\u003c\/li\u003e\n\u003cli\u003eDust cover\u003c\/li\u003e\n\u003cli\u003eUser manual and warranty card\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAvailable on request:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e10х\/22mm eyepiece with a scale\u003c\/li\u003e\n\u003cli\u003e10x\/22mm eyepiece with a reticle\u003c\/li\u003e\n\u003cli\u003e10x\/22mm eyepiece with crosshairs\u003c\/li\u003e\n\u003cli\u003e12.5x\/16mm eyepiece (2 pcs.)\u003c\/li\u003e\n\u003cli\u003e15x\/16mm eyepiece (2 pcs.)\u003c\/li\u003e\n\u003cli\u003e20x\/12mm eyepiece (2 pcs.)\u003c\/li\u003e\n\u003cli\u003e30x\/8mm eyepiece (2 pcs.)\u003c\/li\u003e\n\u003cli\u003ePlan achromatic objective Plan 2х\/0.06 ∞\/–, parfocal distance: 60mm\u003c\/li\u003e\n\u003cli\u003ePlan achromatic objective Plan 20х\/0.40 ∞\/0.17, parfocal distance: 60mm\u003c\/li\u003e\n\u003cli\u003ePlan achromatic objective Plan 60х\/0.80 ∞\/0.17, parfocal distance: 60mm\u003c\/li\u003e\n\u003cli\u003ePlan apochromatic objective Plan Apo 60x\/1.42 oil ∞\/0.17, parfocal distance: 60mm \u003c\/li\u003e\n\u003cli\u003ePlan achromatic objective Plan 100x\/1.10 water ∞\/0.17, parfocal distance: 60mm\u003c\/li\u003e\n\u003cli\u003ePhase contrast device: phase contrast condenser, set of phase objectives, centering telescope\u003c\/li\u003e\n\u003cli\u003eDarkfield condenser NA 0.7–0.9\u003c\/li\u003e\n\u003cli\u003eDarkfield immersion condenser NA 1.3–1.26\u003c\/li\u003e\n\u003cli\u003eDifferential Interference Contrast (DIC) device \u003c\/li\u003e\n\u003cli\u003eMotorized epi-fluorescence attachment with LED light source, fluorescence filter cubes, and power cord\u003c\/li\u003e\n\u003cli\u003ePolarizer\/analyzer set\u003c\/li\u003e\n\u003cli\u003eCalibration slide\u003c\/li\u003e\n\u003cli\u003eSet of color filters (blue, green, yellow, frosted glass)\u003c\/li\u003e\n\u003cli\u003eC-mount adapter\u003c\/li\u003e\n\u003cli\u003eMonitor and digital camera with HDMI interface\u003c\/li\u003e\n\u003c\/ul\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eMAGUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e2400000065319\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e=== Delimiter ===\u003c\/td\u003e\n\u003ctd\u003eMicroscope specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003ebiological, light\/optical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMicroscope head type\u003c\/td\u003e\n\u003ctd\u003etrinocular\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHead\u003c\/td\u003e\n\u003ctd\u003eGemel head (Siedentopf, 360° rotation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHead inclination angle\u003c\/td\u003e\n\u003ctd\u003e30 °\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagnification, x\u003c\/td\u003e\n\u003ctd\u003e40 — 1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagnification range\u003c\/td\u003e\n\u003ctd\u003efrom 800x to 1280x\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagnification, x (optional)\u003c\/td\u003e\n\u003ctd\u003e40–1250\/1500\/2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC-mount adapter magnification, x\u003c\/td\u003e\n\u003ctd\u003e0.55, 1 (adapter); 0.55 (trinocular tube)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEyepiece tube diameter, mm\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEyepieces\u003c\/td\u003e\n\u003ctd\u003e10x\/22 with diopter adjustment ± 5dp, high eyepoint (*optional: 10x\/22 with a scale, 10x\/22 with a reticle, *10x\/22 with crosshairs, 12.5x\/16, 15x\/16, 20x12, 30x8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eObjectives\u003c\/td\u003e\n\u003ctd\u003efluorescence plan semi-apochromatic, infinity-corrected: 4x\/0.13\/17; 10x\/0.30\/16; 20x\/0.50\/2.7; 40x\/0.75\/1.4; 100x\/1.40 (oil)\/0.18 (*optional: Plan 2x\/0.06; Plan 20x\/0.40; Plan 60x\/0.80; Plan 100x\/1.10 water; Plan Apo 60x\/1.42 oil); parfocal distance: 60mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRevolving nosepiece\u003c\/td\u003e\n\u003ctd\u003e5 objectives, coded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking distance, mm\u003c\/td\u003e\n\u003ctd\u003e30 (4x); 10.2 (10x); 1.5 (40x); 0.2 (100xs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterpupillary distance, mm\u003c\/td\u003e\n\u003ctd\u003e47 — 75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStage, mm\u003c\/td\u003e\n\u003ctd\u003e235x150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStage moving range, mm\u003c\/td\u003e\n\u003ctd\u003e78\/54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStage features\u003c\/td\u003e\n\u003ctd\u003etwo-axis mechanical stage, without a positioning rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEyepiece diopter adjustment, diopters\u003c\/td\u003e\n\u003ctd\u003e±5D on each eyepiece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEyepiece diopter adjustment\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCondenser\u003c\/td\u003e\n\u003ctd\u003eAbbe condenser, N.A. 0.9, center-adjustable, height-adjustable, adjustable diaphragm, dovetail mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiaphragm\u003c\/td\u003e\n\u003ctd\u003eadjustable aperture diaphragm, adjustable iris field diaphragm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFocus\u003c\/td\u003e\n\u003ctd\u003ecoaxial, coarse (32mm, 18.85mm\/circle, with a lock knob and tension adjusting knob) and fine (0.001mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIllumination\u003c\/td\u003e\n\u003ctd\u003eLED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e100–240V, 50\/60Hz, AC network, the AC\/DC power adapter is located in a special socket on the back of the stand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight source type\u003c\/td\u003e\n\u003ctd\u003e3W LED, with color temperature adjustment (3000–7000K)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature range, °C\u003c\/td\u003e\n\u003ctd\u003e5 — 30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional\u003c\/td\u003e\n\u003ctd\u003eautomatic brightness adjustment when switching objectives, eco mode, sleep mode, status display on LCD screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbility to connect additional equipment\u003c\/td\u003e\n\u003ctd\u003edarkfield condenser (dry or oil), device for working with the differential interference contrast (DIC) method , epi-fluorescence attachment, phase contrast device (condenser and objectives), polarization devices (polarizer and analyzer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser level\u003c\/td\u003e\n\u003ctd\u003eexperienced users, professionals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssembly and installation difficulty level\u003c\/td\u003e\n\u003ctd\u003ecomplicated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003elaboratory\/medical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIllumination location\u003c\/td\u003e\n\u003ctd\u003elower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResearch method\u003c\/td\u003e\n\u003ctd\u003ebright field\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePouch\/case\/bag in set\u003c\/td\u003e\n\u003ctd\u003edust cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e=== Delimiter ===\u003c\/td\u003e\n\u003ctd\u003eCamera specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor\u003c\/td\u003e\n\u003ctd\u003eSONY Exmor CMOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor\/monochrome\u003c\/td\u003e\n\u003ctd\u003ecolor \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum resolution, pix\u003c\/td\u003e\n\u003ctd\u003e1600x1100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor size\u003c\/td\u003e\n\u003ctd\u003e1.1\" (14.4x9.9mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePixel size, μm\u003c\/td\u003e\n\u003ctd\u003e9.0x9.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTwo-stage thermoelectric module (Peltier element) to set the temperature 42°C below room temperature\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight sensitivity\u003c\/td\u003e\n\u003ctd\u003e4910mV with 1\/30s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal\/noise ratio\u003c\/td\u003e\n\u003ctd\u003e0.3mV with 1\/30s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExposure time\u003c\/td\u003e\n\u003ctd\u003e0.1ms–1h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVideo recording\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame rate, fps at resolution\u003c\/td\u003e\n\u003ctd\u003e33@1600x1100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlace of installation\u003c\/td\u003e\n\u003ctd\u003etrinocular tube\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImage format\u003c\/td\u003e\n\u003ctd\u003e*.jpg, *.bmp, *.png, *.tif\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVideo format\u003c\/td\u003e\n\u003ctd\u003eoutput: *.wmv, *.avi, *.h264 (Windows 8 and later), *h265 (Windows 10 and later)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpectral range, nm\u003c\/td\u003e\n\u003ctd\u003e380–650 (built-in IR filter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShutter type\u003c\/td\u003e\n\u003ctd\u003eGlobal shutter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWhite balance\u003c\/td\u003e\n\u003ctd\u003eautomatic, manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExposure control\u003c\/td\u003e\n\u003ctd\u003eautomatic, manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware features\u003c\/td\u003e\n\u003ctd\u003ebrightness, exposure time, image size\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware\u003c\/td\u003e\n\u003ctd\u003eMAGUS View\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput\u003c\/td\u003e\n\u003ctd\u003e5Gb\/s, USB 3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem requirements\u003c\/td\u003e\n\u003ctd\u003eWindows 8\/10\/11 (32bit and 64bit), Mac OS X, Linux, up to 2.8GHz Intel Core 2 or higher, minimum 2GB RAM, USB 3.0 port, CD-ROM, 17\" or larger display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount type\u003c\/td\u003e\n\u003ctd\u003eC-mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody\u003c\/td\u003e\n\u003ctd\u003eCNC aluminum alloy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCamera operating temperature range, °С\u003c\/td\u003e\n\u003ctd\u003e-10 — 50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"MAGUS","offers":[{"title":"Default title","offer_id":55589051531593,"sku":"86355","price":13672.09,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0426\/8032\/0154\/files\/86355_magus-lum-d470l-microscope-digital_00.jpg?v=1791822325","url":"https:\/\/madeiraoptics.com\/es-eu\/products\/magus-lum-d470l-fluorescence-digital-microscope","provider":"Madeira Optics","version":"1.0","type":"link"}