{"product_id":"ermenrich-zing-dz70-digital-clamp-meter","title":"Ermenrich Zing DZ70 Digital Clamp Meter","description":"\u003cp\u003eThe Ermenrich Zing DZ70 is a professional measuring tool for electricians, HVAC specialists, and power electronics technicians. The device measures AC and DC current up to 1,000A without breaking the circuit, and it also replaces a multimeter. It features capacitance measurement up to 40mF, temperature from −40°C to +1,000°C, frequency, and duty cycle.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAccurate measurements with distorted signals\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe device measures true root mean square (True RMS). Therefore, readings remain accurate even when the waveform is far from sinusoidal: in server equipment circuits, switching power supplies, LED lighting, and variable frequency drive power circuits. The clamp meter measures AC and DC current up to 1,000A and voltage up to 600V. This is sufficient for residential electrical systems and most 230\/400V industrial networks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWide capacitance measurement range\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe capacitance measurement limit of this model is 40mF (40,000µF), whereas many budget multimeters are limited to hundreds of microfarads. With the Ermenrich Zing DZ70, you can test large smoothing capacitors in welding inverters, industrial rectifiers, and high-power audio amplifiers. The frequency meter with a 4kHz limit and the duty cycle measurement function are suitable for monitoring mains frequency and low-frequency PWM signals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHVAC and refrigeration equipment maintenance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe device is highly useful for HVAC (heating, ventilation, and air conditioning) specialists. With the thermocouple, it is convenient to check the operation of air conditioners, freezers, and heat pumps as well as monitor the temperature of refrigerant lines. The temperature measurement range is −40°C to +1,000°C. The device is designed to operate at ambient temperatures from −10°C to +50°C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostics and ease of use\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe audible continuity test triggers at a resistance below 35Ω. This low threshold reduces the risk of false triggers, and a test current of less than 1mA is safe for electronic components. The diode test mode helps you to quickly find faulty semiconductors. Readings are displayed on a 4,000-count screen with a backlight. The device complies with IEC 61010-1 (CAT III 600V) and is powered by a single 9V battery (not included).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTrue RMS ensures accurate measurements in networks that are affected by interference from variable frequency drives and switching power supplies\u003c\/li\u003e\n\u003cli\u003eHigh currents up to 1,000A (DC\/AC) enable safe diagnostics of power mains and busbars without shutting down equipment \u003c\/li\u003e\n\u003cli\u003eHigh capacitance (up to 40mF) helps identify faulty large capacitors in welding inverters and high-power audio equipment\u003c\/li\u003e\n\u003cli\u003eThermocouple with measurement from −40°C can be used for setting up refrigeration units, chillers, and refrigerant circuits\u003c\/li\u003e\n\u003cli\u003ePrecise continuity test (\u0026lt; 35Ω): instant location of short circuits on PCBs without false triggers\u003c\/li\u003e\n\u003cli\u003eReliable protection: CAT III 600V overvoltage category for work in distribution panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eThe kit includes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDigital clamp meter\u003c\/li\u003e\n\u003cli\u003eProbe – 2 pcs.\u003c\/li\u003e\n\u003cli\u003eThermocouple\u003c\/li\u003e\n\u003cli\u003ePouch\u003c\/li\u003e\n\u003cli\u003eUser manual and warranty card\u003c\/li\u003e\n\u003c\/ul\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eErmenrich\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e5905555028736\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage size (LxWxH)\u003c\/td\u003e\n\u003ctd\u003e24x14x6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e0.61 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelection of the measuring limit\u003c\/td\u003e\n\u003ctd\u003eautomatic, manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBasic functions \u003c\/td\u003e\n\u003ctd\u003eammeter, capacitance meter, duty cycle meter, frequency meter, ohmmeter, thermocouple, voltmeter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC voltage measuring limit\u003c\/td\u003e\n\u003ctd\u003e400mV: accuracy ±(0.8%+2); 4V\/40V\/400V: accuracy ±(1.5%+2); 600V: accuracy ±(2.0%+2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC voltage measuring limit\u003c\/td\u003e\n\u003ctd\u003e400mV: accuracy ±(1.0%+10); 4V\/40V\/400V: accuracy ±(1.5%+8); 600V: accuracy ±(2.0%+8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC current measuring limit\u003c\/td\u003e\n\u003ctd\u003e40A: accuracy ±(2.8%+10); 400A: accuracy ±(2.8%+8); 1,000A: accuracy ±(3.0%+8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC current measuring limit\u003c\/td\u003e\n\u003ctd\u003e40A: accuracy ±(2.8%+10); 400A: accuracy ±(2.8%+8); 1,000A: accuracy ±(3.0%+8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance measuring limit\u003c\/td\u003e\n\u003ctd\u003e400Ω: accuracy ±(1.0%+4); 4kΩ\/40kΩ\/400kΩ: accuracy ±(1.5%+2); 4MΩ: accuracy ±(2.5%+5); 40MΩ: accuracy ±(3.5%+10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacity measuring limit\u003c\/td\u003e\n\u003ctd\u003e4nF: accuracy ±(5.0%+30); 40nF: accuracy ±(5.0%+20); 400nF\/4µF\/40µF: accuracy ±(3.0%+5); 400µF: accuracy ±(4.0%+10); 4mF: accuracy ±(4.5%+10); 40mF: accuracy ±(4.5%+10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency measurement limits\u003c\/td\u003e\n\u003ctd\u003e4kHz: accuracy ±(1.5%+2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDuty cycle measurement range\u003c\/td\u003e\n\u003ctd\u003e0.5–99.0%: accuracy ±(1.2%+2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature measurement range\u003c\/td\u003e\n\u003ctd\u003e–40...+1,000°C: accuracy ±(2.5%+3°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire mapping\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity test\u003c\/td\u003e\n\u003ctd\u003e+, threshold \u0026lt;35Ω, test current \u0026lt;1mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiodes test\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiode test\u003c\/td\u003e\n\u003ctd\u003e+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrue RMS \u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHold function\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLimit value function (Min\/Max)\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDCA Zero\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput impedance\u003c\/td\u003e\n\u003ctd\u003e10MΩ (DC and AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThroughput capacitance\u003c\/td\u003e\n\u003ctd\u003e50\/60Hz (AAC\/VAC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay counts\u003c\/td\u003e\n\u003ctd\u003e4000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay backlight\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage category\u003c\/td\u003e\n\u003ctd\u003eCAT III 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature range, °C\u003c\/td\u003e\n\u003ctd\u003e-10 — 50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e9V battery – 1 pc. (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto power off\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Ermenrich","offers":[{"title":"Default title","offer_id":55934990057801,"sku":"87506","price":94.22,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0426\/8032\/0154\/files\/87506_ermenrich-zing-dz70-digital-clamp-meter_00.jpg?v=1794588701","url":"https:\/\/madeiraoptics.com\/es-eu\/products\/ermenrich-zing-dz70-digital-clamp-meter","provider":"Madeira Optics","version":"1.0","type":"link"}