La mayoría de nuestros pedidos se envían en 2 días laborables*.
Tenemos una política de devoluciones de 14 días. Si no está satisfecho con su compra, por favor devuélvala en su embalaje original y asegúrese de poner el embalaje original del producto dentro de la caja de envío para evitar cualquier daño. Todos los artículos deben estar en su estado original y sin usar. Se reembolsará el valor de su compra. No se reembolsarán los gastos de envío.
Microscope is designed for observing specimens in reflected light using the fluorescence technique and in transmitted light using the brightfield technique. With optional accessories, you can also use darkfield, simple polarization, and phase-contrast techniques. The coded revolving nosepiece maintains a comfortable brightness level when the objectives are changed. The microscope's intelligent lighting control system improves comfort and speed of the researcher’s everyday work. Smart features help students ease into the profession and gain the professional experience they need. The fluorescence technique is based on the ability of substances to emit the light when excited by the light of a certain wavelength. On the MAGUS Lum D460L LCD, specimens are excited with blue, green, and ultraviolet light. The wavelength of the emitted light is longer than the wavelength of the excitation light. Some specimens exhibit autofluorescence, while others should be treated with fluorochromes. The microscope is equipped with an 8MP camera and three video interfaces: HDMI, USB 3.0, and Wi-Fi. It can be connected simultaneously to several devices: monitor, laptop, and desktop computer. The software complements the system with analysis and documentation functions. The monitor in a digital microscope has 4K resolution. The microscope is used in medical institutions and laboratories, research organizations, forensic centers, industrial and environmental organizations, pharmaceutical companies, and educational institutions.
Digital camera
MAGUS CHD40 is a digital HDMI camera with three video interfaces and automatic switching between 4K and Full HD depending on the monitor resolution. The camera is equipped with an 8MP sensor and it produces a realistic image in 4K resolution (3840x2160 pixels) when connected via HDMI or USB 3.0. When connected via Wi-Fi, the image resolution is Full HD (1920x1080 pixels). The camera uses an HDMI interface to connect directly to a TV, monitor, or projector. In this mode, the camera operates autonomously without a PC. The HDMI interface provides a high and stable transfer rate from the camera to the external screen. The connection to a computer is made via Wi-Fi or USB 3.0. Video is recorded at 30fps. The camera combines high FPS and high bandwidth HDMI and, therefore, videos are vivid with no freezes or gaps between frames. At maximum resolution, the image is well-detailed, moving objects are visible without any bugs, and object movement is displayed without delays.
Monitor
The MAGUS MCD40 Monitor is designed to use a visualization system of the MAGUS microscope. It connects to a microscope-mounted camera to display a real-time image. It is compatible with MAGUS HDMI cameras operating in 4K resolution. The screen diagonal is 13.3 inches. The IPS sensor delivers a bright image with large viewing angles: If you look at the monitor at an angle, there is no color distortion. The display can be placed on a folding stand on a table or mounted directly on the camera, whichever is more convenient for the user.
Microscope head
Trinocular, with infinity-corrected optics. The eyepiece tubes are 360° rotatable. The user can adjust the eyepiece height to suit their individual stature. The digital camera is mounted in the trinocular tube. The beam splitting ratio is fixed at 50/50. The vertical tube provides 0.55x magnification. When paired with the included 1x adapter, the final magnification at the camera is 0.55x. When calculating the field of view and on-screen magnification for each objective, use a total factor of 0.55x. The basic configuration includes 10x/22mm eyepieces with diopter adjustment and eye relief to work with glasses. Flat rubber eyecups protect eyeglasses from scratches.
Revolving nosepiece and objectives
The coded revolver for five objectives is oriented toward the interior: The user can see the objective inserted into the optical path, and the space above the stage is free. An additional objective can also be installed in the free slot in order to achieve extra magnification. The parfocal distance is 60mm. The 40x objective with its extended working distance of 1.5mm provides additional protection for the front lens against immersion oil contact when rotating the nosepiece. Above the revolver, there is a slot with a plug for the analyzer.
Maintaining a comfortable brightness level in transmitted light when changing magnifications The objectives of different magnifications transmit light with different levels of intensity, and so each time you change objectives, the brightness of the light must be adjusted. Switching from a higher to a lower magnification objective causes eye fatigue, as the image brightness in the eyepieces increases sharply. The MAGUS Lum D460L LCD, which is equipped with intelligent brightness control, solves this problem. The microscope remembers the brightness for each objective that the user has selected and automatically sets this brightness when turning the nosepiece. Intelligent control reduces the time required to adjust brightness. MAGUS Lum D460L LCD increases user comfort and saves you time even when your work requires frequent magnification changes.
Focusing mechanism
Coaxial coarse & fine focusing knobs. The coarse focusing knob is located on the left side. Fine focusing knobs are located on both sides, the right knob having special finger indentations. The ring on the left side adjusts the tension of the coarse focusing travel. The user adjusts the comfortable tension for work.
Stage
The stage has no X-axis rack and pinion, which improves ergonomics. The belt-driven mechanism allows for smooth movement of the specimen. The specimen holder is secured with two screws and can be easily removed during manual scanning. The long stage control handle ensures user comfort: The hand rests on the table with no strain.
Motorized fluorescence attachment
There is a 4-position rotating turret inside the attachment with three broadband fluorescence filters of different wavelengths: blue (B), green (G), and ultraviolet (UV). The required filter is introduced into the optical path by clicking the button. One button on the attachment rotates the turret to the next filter clockwise, and the other one rotates the turret counterclockwise. One position of the turret corresponds to brightfield observations in transmitted light. The excitation light sources are LEDs. The LEDs instantly reach the brightness that is set by the user. They do not heat up during prolonged use and can switch off quickly, if necessary. This makes it easy to switch from the brightfield technique to fluorescence and back again. The brightness of the LEDs is controlled by two additional buttons that are located in the same work area as the turret switching buttons. The LED lifetime is 50,000 hours. It is recommended to choose LED-based fluorescence for higher education as it is the safest option and requires minimal maintenance.
Köhler illumination in transmitted light
Properly setting up Köhler illumination enhances the image quality of a specimen. With such illumination, you achieve maximum resolution for each objective and an evenly illuminated field of view with no darkening at the edges. The object of study is in sharp focus and the image artifacts are removed.
Condenser
The condenser is height-adjustable and can be centered. Mounting type: dovetail. The condenser ring adjusts the iris aperture diaphragm. The condenser body has a marking for the magnification of the objectives, and the ring has an indicator marker. To achieve contrast on each objective, it is recommended to rotate the ring so that the index marker matches the magnification marking of the objective being used. The condenser has a slot with a plug for a darkfield slider or a phase contrast slider. The installation of a slider saves time when changing the observation method.
Transmitted light source
The transmitted light illuminator uses a 3W LED. The color temperature does not change when you adjust the brightness. The LED lifetime is 50,000 hours.
Status LCD screen
The LCD screen on the base of the microscope displays the objective magnification, brightness of the light source, and operating mode (“sleep” and “eco”). Using the screen and two knobs, the microscope user adjusts the brightness, locks the brightness adjustment, and sets the sleep mode and auto-off timer.
Ergonomic design
Physical discomfort causes fatigue and reduces productivity. The ergonomic design of the microscope plays an important role in everyday scientific research. MAGUS Lum D460L LCD provides user comfort during operation. By rotating the eyepiece tubes, the user can adjust the viewing height to prevent back and neck strain. Focusing knobs are located at the bottom of the body. The user does not need to strain their hands. Thanks to the smooth movement of the mechanism, the user can effortlessly focus on the object. The microscope is operated with minimal hand movement, since the long stage control handle and fine focusing knob are located in the same working area. The microscope is equipped with a special carrying handle. The design for the hidden placement of the power cord improves the workplace esthetic and safety of carrying the microscope as well as simplifies storage of the device.
Accessories
There is a line of accessories designed specifically for this microscope. Optional objectives provide additional magnification. Eyepieces extend the magnification range of the microscope. Optional eyepieces help you maximize the potential of the objective that you use most often. The phase contrast device, darkfield slider, and polarizer/analyzer set offer more contrast techniques so that you can study specimens that are invisible in brightfield. A calibration slide is used to measure objects and can be combined with the eyepiece with a scale or with the camera software.
Alternative models
MAGUS Lum D460L LCD is an alternative for the following models: Carl Zeiss Primostar 3, Leica DM 1000, Leica DM 1000LED, Leica DM 2000, Leica DM 2000LED, Olympus CX 33.
Microscope features:
Camera features:
Monitor features:
Package:
Available on request:
| Brand | MAGUS |
| EAN | 2400000065302 |
| Type | biological, light/optical |
| Microscope head type | trinocular |
| Head | Gemel head (Siedentopf, 360° rotation) |
| Head inclination angle | 30 ° |
| Magnification, x | 40 — 1000 |
| Magnification, x | 40–1000 basic configuration (*optional: 40–1250/1500/2000) |
| C-mount adapter magnification, x | 0.55 |
| Eyepiece tube diameter, mm | 30 |
| Eyepieces | 10x/22 with diopter adjustment ± 5dp, high eyepoint (*optional: 10x/22 with a scale, 10x/22 with a reticle, *10x/22 with crosshairs, 12.5x/16, 15x/16, 20x12, 30x8) |
| Objectives | 4x/0.10/30; 10x/0.25/10.2; 40x/0.65/1.5; 100x/1.25 oil/0.2 (*optional: 2x/0.06; 20x/0.40; 60x/0.80; 100x/1.10 (water); Plan Apo 60x/1.42 (oil); set of plan semi-apochromatic fluorescence objectives 4x/10x/20x/40x/100x (oil) |
| Revolving nosepiece | 5 objectives, coded |
| Interpupillary distance, mm | 47 — 78 |
| Stage, mm | 230x150 |
| Stage moving range, mm | 78x54 |
| Coarse focusing travel, mm | 30 |
| Stage features | rackless XY mechanical stage |
| Eyepiece diopter adjustment, diopters | ±5 |
| Eyepiece diopter adjustment | yes |
| Condenser | Abbe condenser, N.A. 1.25, center-adjustable, height-adjustable, adjustable aperture diaphragm, a slot for a darkfield slider and phase contrast slider, dovetail mount |
| Diaphragm | adjustable iris |
| Focus | coaxial coarse & fine focusing knobs; coarse focusing knob on the left side; fine focusing knobs on both sides |
| Illumination | LED |
| Brightness adjustment | yes |
| Power supply | AC power supply, 100–240/50/60 |
| Light source type | 3W LED |
| Operating temperature range, °C | 0 — 70 |
| Additional | automatic brightness adjustment when switching objectives, eco mode, sleep mode, status display on LCD screen |
| User level | experienced users, professionals |
| Assembly and installation difficulty level | complicated |
| Fluorescence filter: filter type, excitation wavelength/dichroic mirror/emission wavelength | blue (B), 460–495nm / 505nm / 510nm; green (G), 510–550nm / 570nm / 575nm; ultraviolet (UV), 330–385nm / 410nm / 420nm |
| Application | laboratory/medical |
| Illumination location | lower |
| Research method | bright field |
| Pouch/case/bag in set | dust cover |
| Sensor | Sony Exmor/Starvis CMOS |
| Color/monochrome | color |
| Megapixels | 8 |
| Maximum resolution, pix | 3840x2160 |
| Sensor size | 1/1.2'' (11.14x6.26mm) |
| Pixel size, μm | 2.9x2.9 |
| Interface connectors | HDMI 1.4, USB 3.0, Wi-Fi |
| Memory card | SD up to 32GB |
| Ability to connect additional equipment | USB mouse, Wi-Fi adapter (USB), flash stick (USB) |
| Light sensitivity | 1028mV with 1/30s |
| Signal/noise ratio | 0.13mV at 1/30s |
| Exposure time | 0.014ms–1000ms |
| Video recording | yes |
| Frame rate, fps at resolution | 30@1920x1080 (Wi-Fi), 30@3840x2160 (HDMI), 30@3840x2160 (USB3.0) |
| Place of installation | trinocular tube, eyepiece tube instead of an eyepiece |
| Image format | *.jpg, *.tif |
| Video format | *.h264/*.h265, *.mp4 |
| Spectral range, nm | 380–650 (IR-filtered) |
| Shutter type | ERS (electronic rolling shutter) |
| Software | HDMI: built-in; USB: MAGUS View |
| System requirements | Windows 8/10/11 (32bit and 64bit), Mac OS X, Linux, up to 2.8GHz Intel Core 2 or higher, minimum 4GB RAM, USB2.0 port, RJ45, 19" or larger display |
| Mount type | C-mount |
| Body | cast aluminum |
| Camera power supply | AC adapter 12V, 1A |
| Specifications of the AC power adapter | input: AC voltage 100–240V, 50/60Hz, output: DC voltage 12V/1A |
| Camera operating temperature range, °С | -10 — 50 |
| Operating humidity range, % | 30 — 80 |
| Type of matrix | IPS |
| Display diagonal, inch | 13.3 |
| Display resolution, px | 3840x2160 (4K) |
| Aspect ratio | 16:9 |
| Brightness, cd/m² | 400 |
| Number of displayed colors | 16.7 m |
| Contrast | 1000:1 |
| Horizontal/vertical viewing angle, ° | 178/178 |
| Size of the visible screen area (WxH), mm | 295x165 |
| Pixel pitch (WxH), mm | 0.154x0.154 |
| Frequency of optical source, Hz | 60 |
| Type of matrix backlight | LED |
| LED backlight lifetime, h | 50000 |
| Interface | HDMI |
| Operating temperature range, °C | -15 — 55 |
| Operating humidity range, % | 10 — 90 |
| Power supply | AC 110–220V, DC 5–12V/1A (Type-C) |
| Power consumption, W | 12 (max.) |
Tenemos una política de devoluciones de 14 días. Si usted no está satisfecho con su compra, por favor devuélvalo en su embalaje original y asegúrese de poner el embalaje original del producto dentro de la caja de envío para evitar cualquier daño....
Todos los artículos deben estar en su estado original y sin usar. Se le reembolsará el valor de su compra. .
No se reembolsarán los gastos de envío.
Si la devolución se debe a un producto defectuoso, es posible que se le compensen los gastos de envío de la devolución.
Póngase en contacto con nosotros para obtener más detalles si necesita realizar una devolución....
- De 0 a 2 kg - gastos de envío: 12,50 euros.
- De 2,001 kg a 30 kg - gastos de envío: 17,00 euros.
- A partir de 30,001 kg - gastos de envío: 30,00 euros.
En caso de recogida en nuestro almacén o puntos de reventa - el envío es gratuito.
Gracias por suscribirse.
¡Este correo electrónico ha sido registrado!