{"product_id":"magus-lum-460l-fluorescence-microscope","title":"MAGUS Lum 460L Fluorescence Microscope","description":"\u003cp\u003eMicroscope is designed for observing specimens in reflected light using the fluorescence technique and in transmitted light using the brightfield technique. With optional accessories, you can also use darkfield, simple polarization, and phase-contrast techniques.\nThe coded revolving nosepiece maintains a comfortable brightness level when the objectives are changed. The microscope's intelligent lighting control system improves comfort and speed of the researcher’s everyday work. Smart features help students ease into the profession and gain the professional experience they need.\nThe fluorescence technique is based on the ability of substances to emit the light when excited by the light of a certain wavelength. On the MAGUS Lum 460L, specimens are excited with blue, green, and ultraviolet light. The wavelength of the emitted light is longer than the wavelength of the excitation light. Some specimens exhibit autofluorescence, while others should be treated with fluorochromes.\nThe microscope is used in medical institutions and laboratories, research organizations, forensic centers, industrial and environmental organizations, pharmaceutical companies, and educational institutions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMicroscope head\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTrinocular, with infinity-corrected optics. The eyepiece tubes are 360° rotatable. The user can adjust the eyepiece height to suit their individual stature. The digital camera is mounted in the trinocular tube. The beam splitting ratio is fixed at 50\/50.\nThe vertical tube provides 0.55x magnification. When paired with the included 1x adapter, the final magnification at the camera is 0.55x. When selecting a camera and calculating the resolution and sensor size, use the final magnification factor of 0.55x.\nThe basic configuration includes 10x\/22mm eyepieces with diopter adjustment and eye relief to work with glasses. Flat rubber eyecups protect eyeglasses from scratches.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRevolving nosepiece and objectives\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe coded revolver for five objectives is oriented toward the interior: The user can see the objective inserted into the optical path, and the space above the stage is free. An additional objective can also be installed in the free slot in order to achieve extra magnification. The parfocal distance is 60mm.\nThe 40x objective with its extended working distance of 1.5mm provides additional protection for the front lens against immersion oil contact when rotating the nosepiece.\nAbove the revolver, there is a slot with a plug for the analyzer.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaintaining a comfortable brightness level in transmitted light when changing magnifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe objectives of different magnifications transmit light with different levels of intensity, and so each time you change objectives, the brightness of the light must be adjusted. Switching from a higher to a lower magnification objective causes eye fatigue, as the image brightness in the eyepieces increases sharply. The MAGUS Lum 460L, which is equipped with intelligent brightness control, solves this problem. The microscope remembers the brightness for each objective that the user has selected and automatically sets this brightness when turning the nosepiece. Intelligent control reduces the time required to adjust brightness. MAGUS Lum 460L increases user comfort and saves you time even when your work requires frequent magnification changes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFocusing mechanism\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCoaxial coarse \u0026amp; fine focusing knobs.\nThe coarse focusing knob is located on the left side. Fine focusing knobs are located on both sides, the right knob having special finger indentations.\nThe ring on the left side adjusts the tension of the coarse focusing travel. The user adjusts the comfortable tension for work.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStage\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe stage has no X-axis rack and pinion, which improves ergonomics. The belt-driven mechanism allows for smooth movement of the specimen. The specimen holder is secured with two screws and can be easily removed during manual scanning.\nThe long stage control handle ensures user comfort: The hand rests on the table with no strain.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMotorized fluorescence attachment\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThere is a 4-position rotating turret inside the attachment with three broadband fluorescence filters of different wavelengths: blue (В), green (G), and ultraviolet (UV). The required filter is introduced into the optical path by clicking the button. One button on the attachment rotates the turret to the next filter clockwise, and the other one rotates the turret counterclockwise. One position of the turret corresponds to brightfield observations in transmitted light.\nThe excitation light sources are LEDs. The LEDs instantly reach the brightness that is set by the user. They do not heat up during prolonged use and can switch off quickly, if necessary. This makes it easy to switch from the brightfield technique to fluorescence and back again. The brightness of the LEDs is controlled by two additional buttons that are located in the same work area as the turret switching buttons. The LED lifetime is 50,000 hours. \nIt is recommended to choose LED-based fluorescence for higher education as it is the safest option and requires minimal maintenance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKöhler illumination in transmitted light\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eProperly setting up Köhler illumination enhances the image quality of a specimen. With such illumination, you achieve maximum resolution for each objective and an evenly illuminated field of view with no darkening at the edges. The object of study is in sharp focus and the image artifacts are removed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCondenser\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe condenser is height-adjustable and can be centered. Mounting type: dovetail.\nThe condenser ring adjusts the iris aperture diaphragm. The condenser body has a marking for the magnification of the objectives, and the ring has an indicator marker. To achieve contrast on each objective, it is recommended to rotate the ring so that the index marker matches the magnification marking of the objective being used.\nThe condenser has a slot with a plug for a darkfield slider or a phase contrast slider. The installation of a slider saves time when changing the observation method.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTransmitted light source\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe transmitted light illuminator uses a 3W LED. The color temperature does not change when you adjust the brightness. The LED lifetime is 50,000 hours.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStatus LCD screen\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe LCD screen on the base of the microscope displays the objective magnification, brightness and color temperature of the light source, and operating mode (“sleep” and “eco”).\nUsing the screen and two knobs, the microscope user adjusts the brightness, locks the brightness adjustment, and sets the sleep mode and auto-off timer.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eErgonomic design\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePhysical discomfort causes fatigue and reduces productivity. The ergonomic design of the microscope plays an important role in everyday scientific research. \nMAGUS Lum 460L provides user comfort during operation.\nBy rotating the eyepiece tubes, the user can adjust the viewing height to prevent back and neck strain.\nFocusing knobs are located at the bottom of the body. The user does not need to strain their hands. Thanks to the smooth movement of the mechanism, the user can effortlessly focus on the object. \nThe microscope is operated with minimal hand movement, since the long stage control handle and fine focusing knob are located in the same working area.\nThe microscope is equipped with a special carrying handle.\nThe design for the hidden placement of the power cord improves the workplace esthetic and safety of carrying the microscope as well as simplifies storage of the device.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAccessories\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThere is a line of accessories designed specifically for this microscope.\nOptional objectives provide additional magnification.\nEyepieces extend the magnification range of the microscope. Optional eyepieces help you maximize the potential of the objective that you use most often.\nThe phase contrast device, darkfield slider, and polarizer\/analyzer set offer more contrast techniques so that you can study specimens that are invisible in brightfield.\nDigital cameras output the microscope image to a monitor, store files, and the software takes real-time measurements of specimens. An optional adapter increases the magnification of the specimen image on the monitor. \nA calibration slide is used to measure objects and can be combined with the eyepiece with a scale or with the camera software.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlternative models\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMAGUS Lum 460L is an alternative for the following models: Carl Zeiss Primostar 3, Leica DM 1000, Leica DM 1000LED, Leica DM 2000, Leica DM 2000LED, Olympus CX 33. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMain features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eStudy of specimens emitting fluorescence when exposed to excitation light\u003c\/li\u003e\n\u003cli\u003eMicroscopy techniques: fluorescence in reflected light, brightfield in transmitted light\u003c\/li\u003e\n\u003cli\u003eTrinocular head with height adjustment to accommodate the observer, a vertical tube for mounting a digital camera, and 50\/50 beam splitting\u003c\/li\u003e\n\u003cli\u003eCoded revolving nosepiece: The brightness of the light source is set automatically depending on the selected objective\u003c\/li\u003e\n\u003cli\u003eTransmitted light illuminator is energy-saving 3W LED with a lifetime of up to 50,000 hours\u003c\/li\u003e\n\u003cli\u003eTransmitted Köhler illumination, centered and height-adjustable condenser with objective magnification markings\u003c\/li\u003e\n\u003cli\u003eSmart transmitted light control system: automatic brightness selection, brightness adjustment lock, auto-off timer, LCD operating status screen\u003c\/li\u003e\n\u003cli\u003eStage without an X-axis positioning rack and with a long control handle for convenient operation\u003c\/li\u003e\n\u003cli\u003eErgonomic stand with a carrying handle and the hidden placement of the power cord\u003c\/li\u003e\n\u003cli\u003eWide range of compatible optional accessories\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePackage:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eStand with a built-in power supply, transmitted light source, focusing mechanism, stage, condenser mount, and revolving nosepiece\u003c\/li\u003e\n\u003cli\u003eAbbe condenser\u003c\/li\u003e\n\u003cli\u003eMotorized fluorescence attachment\u003c\/li\u003e\n\u003cli\u003eB\/G\/UV fluorescence filter cubes\u003c\/li\u003e\n\u003cli\u003eTrinocular microscope head\u003c\/li\u003e\n\u003cli\u003ePlan achromatic objective Plan 4x\/0.10 ∞\/0.17, parfocal distance: 60mm\u003c\/li\u003e\n\u003cli\u003ePlan achromatic objective Plan 10x\/0.25 ∞\/0.17, parfocal distance: 60mm\u003c\/li\u003e\n\u003cli\u003ePlan achromatic objective Plan 40x\/0.65 ∞\/0.17, parfocal distance: 60mm\u003c\/li\u003e\n\u003cli\u003ePlan achromatic objective Plan 100x\/1.25 oil ∞\/0.17 (spring-loaded), parfocal distance: 60mm\u003c\/li\u003e\n\u003cli\u003e10х\/22mm eyepiece with high eyepoint and diopter adjustment (2 pcs.)\u003c\/li\u003e\n\u003cli\u003eEyecup (2 pcs.)\u003c\/li\u003e\n\u003cli\u003eC-mount adapter\u003c\/li\u003e\n\u003cli\u003eMicroscope power cord\u003c\/li\u003e\n\u003cli\u003ePower adapter for a fluorescence attachment\u003c\/li\u003e\n\u003cli\u003eDust cover\u003c\/li\u003e\n\u003cli\u003eUser manual and warranty card\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAvailable on request:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e10х\/22mm eyepiece with a scale\u003c\/li\u003e\n\u003cli\u003e10x\/22mm eyepiece with a reticle\u003c\/li\u003e\n\u003cli\u003e10x\/22mm eyepiece with crosshairs\u003c\/li\u003e\n\u003cli\u003e12.5х\/16mm eyepiece (2 pcs.)\u003c\/li\u003e\n\u003cli\u003e15х\/16mm eyepiece (2 pcs.)\u003c\/li\u003e\n\u003cli\u003e20х\/12mm eyepiece (2 pcs.)\u003c\/li\u003e\n\u003cli\u003e30х\/8mm eyepiece (2 pcs.)\u003c\/li\u003e\n\u003cli\u003ePlan achromatic objective Plan 2х\/0.06 ∞\/–, parfocal distance: 60mm\u003c\/li\u003e\n\u003cli\u003ePlan achromatic objective Plan 20х\/0.40 ∞\/0.17, parfocal distance: 60mm\u003c\/li\u003e\n\u003cli\u003ePlan achromatic objective Plan 60х\/0.80 ∞\/0.17, parfocal distance: 60mm\u003c\/li\u003e\n\u003cli\u003ePlan apochromatic objective Plan Apo 60х\/1.42 oil ∞\/0.17, parfocal distance: 60mm \u003c\/li\u003e\n\u003cli\u003ePlan achromatic objective Plan 100х\/1.10 ∞\/0.17 water, parfocal distance: 60mm\u003c\/li\u003e\n\u003cli\u003eSet of plan semi-apochromatic fluorescence objectives: 4x, 10x, 20x, 40x, 100x (oil); ∞\/0.17; parfocal distance 60mm\u003c\/li\u003e\n\u003cli\u003ePhase contrast device: set of phase sliders, auxiliary centering telescope, set of phase objectives\u003c\/li\u003e\n\u003cli\u003ePhase contrast device: phase contrast condenser, set of phase objectives, auxiliary centering telescope\u003c\/li\u003e\n\u003cli\u003eDarkfield slider\u003c\/li\u003e\n\u003cli\u003eDry darkfield condenser NA 0.7–0.9\u003c\/li\u003e\n\u003cli\u003eOil darkfield condenser NA 1.3–1.26\u003c\/li\u003e\n\u003cli\u003ePolarizer\/analyzer set\u003c\/li\u003e\n\u003cli\u003eDigital camera\u003c\/li\u003e\n\u003cli\u003eCalibration slide\u003c\/li\u003e\n\u003cli\u003eSet of color filters (blue, green, yellow, frosted glass)\u003c\/li\u003e\n\u003cli\u003eC-mount adapter\u003c\/li\u003e\n\u003cli\u003eMonitor\u003c\/li\u003e\n\u003c\/ul\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eMAGUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e2400000066095\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage size (LxWxH)\u003c\/td\u003e\n\u003ctd\u003e47x32x67 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e13.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003ebiological, light\/optical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMicroscope head type\u003c\/td\u003e\n\u003ctd\u003etrinocular\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHead\u003c\/td\u003e\n\u003ctd\u003eGemel head (Siedentopf, 360° rotation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHead inclination angle\u003c\/td\u003e\n\u003ctd\u003e30 °\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagnification, x\u003c\/td\u003e\n\u003ctd\u003e40 — 1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagnification, x\u003c\/td\u003e\n\u003ctd\u003e40–1000 basic (*optional: 40–1250\/1500\/2000\/2500)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC-mount adapter magnification, x\u003c\/td\u003e\n\u003ctd\u003e0.55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEyepiece tube diameter, mm\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEyepieces\u003c\/td\u003e\n\u003ctd\u003e10x\/22 with diopter adjustment ± 5dp, high eyepoint (*optional: 10x\/22 with a scale, 10x\/22 with a reticle, *10x\/22 with crosshairs, 12.5x\/16, 15x\/16, 20x12, 30x8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eObjectives\u003c\/td\u003e\n\u003ctd\u003e4x\/0.10\/30; 10x\/0.25\/10.2; 40x\/0.65\/1.5; 100x\/1.25 oil\/0.2 (*optional: 2x\/0.06; 20x\/0.40; 60x\/0.80; 100x\/1.10 (water); Plan Apo 60x\/1.42 (oil); set of plan semi-apochromatic fluorescence objectives 4x\/10x\/20x\/40x\/100x (oil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRevolving nosepiece\u003c\/td\u003e\n\u003ctd\u003e5 objectives, coded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterpupillary distance, mm\u003c\/td\u003e\n\u003ctd\u003e47 — 78\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStage, mm\u003c\/td\u003e\n\u003ctd\u003e230x150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStage moving range, mm\u003c\/td\u003e\n\u003ctd\u003e78\/54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoarse focusing travel, mm\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStage features\u003c\/td\u003e\n\u003ctd\u003erackless XY mechanical stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEyepiece diopter adjustment, diopters\u003c\/td\u003e\n\u003ctd\u003e±5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEyepiece diopter adjustment\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCondenser\u003c\/td\u003e\n\u003ctd\u003ecenter- and height-adjustable Abbe condenser NA 1.25 with adjustable aperture diaphragm and slot with plug for darkfield and phase contrast sliders; dovetail mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiaphragm\u003c\/td\u003e\n\u003ctd\u003eadjustable iris\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFocus\u003c\/td\u003e\n\u003ctd\u003ecoaxial coarse \u0026amp; fine focusing knobs; coarse focusing knob on the left side; fine focusing knobs on both sides\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIllumination\u003c\/td\u003e\n\u003ctd\u003eLED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrightness adjustment\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003eAC power supply, 100–240\/50\/60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight source type\u003c\/td\u003e\n\u003ctd\u003e3W LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature range, °C\u003c\/td\u003e\n\u003ctd\u003e0 — 70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional\u003c\/td\u003e\n\u003ctd\u003eautomatic brightness adjustment when switching objectives, eco mode, sleep mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser level\u003c\/td\u003e\n\u003ctd\u003eexperienced users, professionals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssembly and installation difficulty level\u003c\/td\u003e\n\u003ctd\u003ecomplicated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluorescence filter: filter type, excitation wavelength\/dichroic mirror\/emission wavelength \u003c\/td\u003e\n\u003ctd\u003eblue (B), 460–495nm \/ 505nm \/ 510nm; green (G), 510–550nm \/ 570nm \/ 575nm; ultraviolet (UV), 330–385nm \/ 410nm \/ 420nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003elaboratory\/medical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIllumination location\u003c\/td\u003e\n\u003ctd\u003elower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResearch method\u003c\/td\u003e\n\u003ctd\u003ebright field\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePouch\/case\/bag in set\u003c\/td\u003e\n\u003ctd\u003edust cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"MAGUS","offers":[{"title":"Default title","offer_id":54570515759433,"sku":"86544","price":9099.95,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0426\/8032\/0154\/files\/86544_magus-lum-460l-microscope_00.jpg?v=1780997477","url":"https:\/\/madeiraoptics.com\/es-es\/products\/magus-lum-460l-fluorescence-microscope","provider":"Madeira Optics","version":"1.0","type":"link"}