{"product_id":"ermenrich-zing-dz60-digital-clamp-meter","title":"Ermenrich Zing DZ60 Digital Clamp Meter","description":"\u003cp\u003eThe Ermenrich Zing DZ60 is a True RMS digital clamp meter that is designed for building maintenance engineers, data center specialists, and HVAC (heating, ventilation, and air conditioning) technicians. The model enables in-depth energy audits and current measurements up to 1,000A without shutting down power at the facility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTrue RMS: accurate readings with distorted waveforms\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSwitching power supplies, dimmers, LED lamps, and inverters distort current and voltage waveforms. Clamp meters without True RMS are designed for pure sine waves and can produce errors in such networks. The Ermenrich Zing DZ60 calculates the true root mean square value and accurately measures AC current and voltage in offices, server rooms, and facilities with LED lighting.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnergy audits and HVAC systems\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 30mm jaw opening and AC\/DC current measurement up to 1,000A make it easy to test the main incoming cables, check phase distribution, and verify the operation of high-power UPS systems or solar power plants. The thermocouple (up to +1,000°C) makes this clamp meter indispensable for HVAC specialists. It conveniently monitors compressor temperatures, refrigerant lines, and radiators as well as helps to locate overheated contacts in electrical panels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh resolution and component-level repair \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 6,000-count display provides excellent measurement resolution. Three-phase network voltage (up to 750V AC and up to 800V DC) is displayed with tenths of a volt without switching to a higher range. The device easily replaces a multimeter for PCB repair. It measures the capacitance of start capacitors (up to 100µF), analyzes PWM signals using the frequency meter (up to 10MHz), and identifies faulty diodes as well as instantly locates open circuits thanks to the sensitive continuity test (\u0026lt; 100Ω).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReliability in any conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe clamp meter operates reliably at temperatures from –10°C to +50°C, making it suitable for use on unheated premises as well as outdoors during transitional seasons. The bright screen backlight is invaluable in dark basements and de-energized rooms. User safety is ensured by the CAT III 600V rating. The device is powered by a single 9V battery (purchased separately), and an auto-off function preserves battery life during prolonged inactivity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTrue RMS ensures accurate AC current and voltage readings with distorted waveforms\u003c\/li\u003e\n\u003cli\u003eAC and DC current up to 1,000A simplifies monitoring of incoming cables, server UPS systems, and solar panels\u003c\/li\u003e\n\u003cli\u003e30mm jaw opening allows convenient work with thick power mains without breaking the circuit\u003c\/li\u003e\n\u003cli\u003eVoltage up to 750V (AC) and 800V (DC) supports testing single-phase and three-phase networks, UPS systems, inverters, and power supplies\u003c\/li\u003e\n\u003cli\u003e6,000-count display delivers high measurement accuracy, including tenths of a volt in three-phase networks\u003c\/li\u003e\n\u003cli\u003eTemperature measurement from –20°C to +1,000°C with a thermocouple helps instantly locate overheated contacts and audit radiators and motors\u003c\/li\u003e\n\u003cli\u003eFull electronics toolkit: capacitance, frequency, duty cycle measurement, fast open-circuit detection, and semiconductor testing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eThe kit includes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDigital clamp meter\u003c\/li\u003e\n\u003cli\u003eProbe – 2 pcs.\u003c\/li\u003e\n\u003cli\u003eThermocouple\u003c\/li\u003e\n\u003cli\u003ePouch\u003c\/li\u003e\n\u003cli\u003eUser manual and warranty card\u003c\/li\u003e\n\u003c\/ul\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eErmenrich\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e5905555028743\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage size (LxWxH)\u003c\/td\u003e\n\u003ctd\u003e22x11x6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e0.55 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelection of the measuring limit\u003c\/td\u003e\n\u003ctd\u003eautomatic, manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBasic functions \u003c\/td\u003e\n\u003ctd\u003eammeter, capacitance meter, duty cycle meter, frequency meter, ohmmeter, thermocouple, voltmeter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC voltage measuring limit\u003c\/td\u003e\n\u003ctd\u003e600mV: accuracy ±(0.8%+3); 6V\/60V\/600V: accuracy ±(1.5%+3); 800V: accuracy ±(2.0%+3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC voltage measuring limit\u003c\/td\u003e\n\u003ctd\u003e600mV: accuracy ±(0.8%+20); 6V\/60V\/600V: accuracy ±(1.8%+5); 750V: accuracy ±(2.5%+5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC current measuring limit\u003c\/td\u003e\n\u003ctd\u003e60A: accuracy ±(2.8%+10); 600A: accuracy ±(2.8%+8); 1,000A: accuracy ±(3.0%+5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC current measuring limit\u003c\/td\u003e\n\u003ctd\u003e60A: accuracy ±(3.0%+10); 600A: accuracy ±(3.0%+8); 1,000A: accuracy ±(3.0%+5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance measuring limit\u003c\/td\u003e\n\u003ctd\u003e600Ω: accuracy ±(1.0%+4); 6kΩ\/60kΩ\/600kΩ: accuracy ±(1.5%+2); 6MΩ: accuracy ±(2.5%+3); 60MΩ: accuracy ±(3.5%+5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacity measuring limit\u003c\/td\u003e\n\u003ctd\u003e40nF: accuracy ±(5.0%+100); 400nF: accuracy ±(3.0%+5); 4µF\/40µF: accuracy ±(3.5%+5); 100µF: accuracy ±(5.0%+5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency measurement limits\u003c\/td\u003e\n\u003ctd\u003e10Hz: accuracy ±(1.5%+5); 100Hz\/1kHz\/10kHz\/100kHz\/1MHz\/10MHz: accuracy ±(1.2%+2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDuty cycle measurement range\u003c\/td\u003e\n\u003ctd\u003e0.5–99.0%: accuracy ±(1.2%+2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature measurement range\u003c\/td\u003e\n\u003ctd\u003e–20...+1,000°C: accuracy ±(3%+5°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire mapping\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity test\u003c\/td\u003e\n\u003ctd\u003e+, threshold \u0026lt;100Ω, test current \u0026lt;1mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiodes test\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiode test\u003c\/td\u003e\n\u003ctd\u003e+, test current 0.3mA, open-circuit voltage 1.5V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrue RMS \u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHold function\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLimit value function (Min\/Max)\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDCA Zero\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput impedance\u003c\/td\u003e\n\u003ctd\u003e7.8MΩ (DC and AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThroughput capacitance\u003c\/td\u003e\n\u003ctd\u003e50\/60Hz (AAC\/VAC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay counts\u003c\/td\u003e\n\u003ctd\u003e6000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay backlight\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage category\u003c\/td\u003e\n\u003ctd\u003eCAT III 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature range, °C\u003c\/td\u003e\n\u003ctd\u003e-10 — 50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e9V battery – 1 pc. (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto power off\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Ermenrich","offers":[{"title":"Default title","offer_id":55934990188873,"sku":"87507","price":104.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0426\/8032\/0154\/files\/87507_ermenrich-zing-dz60-digital-clamp-meter_00.jpg?v=1794588704","url":"https:\/\/madeiraoptics.com\/es-es\/products\/ermenrich-zing-dz60-digital-clamp-meter","provider":"Madeira Optics","version":"1.0","type":"link"}