MAGUS Metal V790 DIC Metallurgical Inverted Microscope
- €18,844.21
- €18,844.21
- Unit price
- per
Fast Shipping
Most of our order are shipped in 2 working days*
Most of our order are shipped in 2 working days*
We have a 14-day return policy. If you are not satisfied with your purchase, please return it in its original packaging and be sure to put the original product packaging inside the shipping box to avoid any damage. All items must be in their original condition and unused. The value of your purchase will be refunded. Shipping charges will not be refunded.
The microscope is designed for studying the microstructure of metals and alloys semiconductor materials and other opaque specimens.
The design of the inverted microscope does not limit the size of the examined sample; only its weight is limited up to 30kg. The specimen must be first specially processed and then it is placed on the stage with the surface down.
This microscope can study opaque objects in reflected light using the brightfield darkfield polarization microscopy and differential interference contrast techniques.
DIC is an advanced polarization contrast technique. The method increases the depth of field and image clarity provides additional information about the structure of the object under study and visualizes irregularities on the studied surfaces with color. Flat surfaces are painted equally but a surface with even minimal differences in height will be uneven in color. The object of study will appear in relief.
The microscope can be used in various fields (metallurgical engineering aerospace nuclear and energy industries) as well as in research laboratories and technical universities.
Microscope head
Trinocular head with infinity-corrected optics. The 45° tilt angle provides comfortable conditions for the researcher to work while sitting or standing. The user can assume a natural pose and therefore fatigue does not accumulate during the workday.
A Bertrand lens is built into the microscope head; a regulator on the front of the head is used to insert it into the optical system. The Bertrand lens is used for conoscopic studies.
The digital camera is installed in the trinocular tube or in one of the side imaging ports on the microscope body. The beam on the trinocular head can be split 100/0 50/50 or 0/100. The beam splitting on the right photo port is 100/0 and 20/80; it is 100/0 and 0/100 on the left.
The basic package includes 10x/23mm eyepieces with diopter adjustment and long eye relief for working with glasses.
Revolving nosepiece
The 5-objectives revolving nosepiece is mounted on the stand under the stage. The differential interference contrast method is implemented using DIC sliders: One is used with low magnification objectives and the other with medium and high magnification objectives. The DIC slider is installed in a special slot of the revolving nosepiece.
Turret for installing contrast modules
Under the objective revolver on the microscope stand there is a turret for installing contrast modules. Six modules can be installed. Rotating the turret changes the observation mode switching from one contrast method to another occurs quickly and without complex settings.
Switch with an additional magnification lens
A rotary switch is used to insert the main 1x lens or an additional 1.5x magnification lens into the optical path. A magnifying lens increases the magnification of a microscope without purchasing or installing additional accessories. The switch is located on the right side of the microscope body under the revolving nosepiece.
Objectives
Semi-apochromatic objectives with a long working distance that are designed for the brightfield and darkfield microscopy techniques. Provide better correction of chromatic and spherical aberration compared to plan achromatic objectives.
Focusing mechanism
Coaxial coarse and fine focusing knobs are located at the base of the microscope on both sides. The right fine focusing handle has special recesses for fingers and the left one has a scale.
The coarse focusing lock knob helps you quickly adjust the microscope after changing the subject of study. The knob is located on the left side of the microscope on the same axis as the focusing mechanism.
The ring on the right side adjusts the tension of the coarse focusing travel. The user adjusts the comfortable tension for work.
Stage
The object is moved by moving the stage along two axes. An insert with a hole of a suitable diameter is installed in the center of the stage. A specimen holder is used to hold the object in place.
The three-layer coating protects the stage from scratches and other surface damage when working with heavy and large samples.
The long tiltable stage control handle ensures user comfort while working: The hand rests on the table without strain. The handle can be installed on the right or left side of the stage.
Light source
The lamphouse has a 100W halogen bulb. It is bright enough to work on objectives with magnifications from 4x to 100x not only in brightfield and polarized light but also in darkfield microscopy techniques. The halogen bulb emits light with a color temperature that allows for comfortable work.
Reflected light illumination
The illumination system makes it possible to set up the Köhler illumination. The field and aperture diaphragms are pre-centered at the factory and require no additional centering. If necessary the diaphragms can be adjusted with centering screws.
The analyzer and polarizer are for the polarization microscopy technique. The polarizer is stationary and the analyzer rotates 360°.
A set of light filters helps you adjust color reproduction.
Ergonomic design
Physical discomfort causes fatigue and reduces productivity. The ergonomic design of the microscope plays an important role in everyday scientific research. The MAGUS Metal V790 DIC provides user comfort during work.
The microscope is operated with minimal hand movement since the long stage control handle and fine focusing knob are located in the same working area.
Focusing knobs are located at the bottom of the body. The user does not strain their hands. Thanks to the smooth movement of the mechanism the user can effortlessly focus on the object.
Key features:
The kit includes:
Available on request:
Brand | MAGUS |
Warranty | 5 лет |
EAN | 5905555019512 |
Package size (LxWxH) | 76x61x58 cm |
Shipping Weight | 34.9 kg |
Head | trinocular |
Head inclination angle | 45 ° |
Magnification range | from 800x to 1280x |
Eyepiece tube diameter mm | 30 |
Objectives | semi-apochromatic objectives infinity-corrected: 5x/0.15; 10x/0.30; 20x/0.45; 50xs/0.80; 100xs/0.90; parfocal height 45mm |
Revolving nosepiece | for 6 objectives with DIC slot |
Working distance mm | 20 (5x); 11 (10x); 3.1 (20x); 1 (50xs); 1 (100xs) |
Interpupillary distance mm | 48 — 75 |
Stage mm | 340x230 |
Stage moving range mm | 130/85 |
Eyepiece diopter adjustment diopters | ±5D on each eyepiece |
Eyepiece diopter adjustment | yes |
Diaphragm | adjustable aperture diaphragm adjustable iris field diaphragm |
Focus | coaxial coarse (10mm with a lock knob and tension adjusting knob) and fine (0.002mm 0.2mm/circle) |
Brightness adjustment | yes |
Operating temperature range °C | 5 — 40 |
Assembly and installation difficulty level | complicated |
Illumination location | upper |
Light source type | 12V/100W |
Type | light/optical metallurgical |
Nozzle | Siedentopf with Bertrand lens beam splitting 100/0 50/50 0/100 |
Magnification x | 50–1000 basic configuration (50–1500x with built-in 1.5x additional magnification lens) |
Eyepieces | 10x/23mm long eye relief (2 pcs.) |
Stage features | two-axis three-layer mechanical with coaxial X/Y handle with low position and tilting capability maximum load 30kg stage inserts |
Illumination | halogen |
Power supply | AC network 220±22V 50Hz |
Light filters | yes |
Additional | polarizer and analyzer DIC sliders for objectives turret for installing contrast modules |
User level | experienced users professionals |
Application | metallurgical |
Research method | bright field dark field polarization DIC |
Pouch/case/bag in set | dust cover |
We have a 14-day return policy. If you are not satisfied with your purchase, please return it in its original packaging and be sure to put the original product packaging inside the shipping box to avoid any damage..
All items must be in their original condition and unused. The value of your purchase will be refunded. .
Shipping charges will not be refunded.
If the return is due to a defective product, you may be compensated for the return shipping.
Please contact us for more details if you need to make a return..
- From 0 to 2 kg - shipping cost: 12,50 euros.
- From 2.001 kg to 30 kg - shipping cost: 17,00 euros.
- From 30,001 kg - shipping cost: 30,00 euros.
In case of collection at our warehouse or resale points - the shipping is free.
Thanks for subscribing!
This email has been registered!