The microscope is designed for studying specimens using the fluorescence microscopy technique in reflected light and brightfield technique in transmitted light. The additional equipment allows for darkfield polarization and phase contrast microscopy. Fluorescence microscopy is based on the ability of some substances to glow when exposed to the light of a certain part of the spectrum. The specimens are exposed to invisible short-wave ultraviolet light or violet blue and green light. The wavelength of the emitted light will be longer than the wavelength of the excitation light. The specimen glows blue cyan green-yellow or red light respectively. Some specimens glow by themselves while others glow after treatment with fluorochromes. The fluorescent microscope is used to study pathogens of tuberculosis chlamydia rabies herpes and other diseases. The microscope can also be used for DNA and chromosome analysis bone marrow and blood smears forensic and pharmacological examination veterinary control studies and sanitary and epidemiological inspection.

Digital camera

MAGUS CHD40 is a digital HDMI camera with three video interfaces and automatic switching between 4K and Full HD depending on the monitor resolution. The camera is equipped with an 8MP sensor and produces realistic images in 4K resolution (3840x2160px) when connected via HDMI or USB3.0. When connected via Wi-Fi the image quality is Full HD (1920x1080px). The camera uses an HDMI interface to connect to a TV monitor or projector directly. In this mode the camera operates autonomously without a connection to a PC. The HDMI interface provides a high and stable transfer rate from the camera to the external screen. You can connect the camera to a PC via Wi-Fi or USB3.0. Video is recorded at 30fps. The camera combines high FPS and high bandwidth HDMI. Therefore videos are vivid with no freezes or gaps between frames. At maximum resolution the image is well-detailed moving objects are visible without bugs and object movement is displayed without delays.

Monitor

The MAGUS MCD40 Monitor is designed to use a visualization system of the MAGUS microscope. It is connected to a camera mounted on the microscope to display real-time images. It supports MAGUS 4K HDMI cameras. The screen diagonal is 13.3 inches. The IPS matrix provides bright images with large viewing angles. If you look at the display at an angle the color reproduction is not distorted. The display can be placed on a folding stand on a table or shelf or mounted directly to the camera or microscope stand.

Microscope head

Trinocular head with infinity-corrected optics. Eyepiece tubes can rotate 360°. The user can adjust eye relief on the eyepiece to fit their height. The digital camera is mounted in the trinocular tube.

Revolving nosepiece

Five objectives. A free slot is used for centering the reflected light source. An additional objective can also be installed in the free slot in order to achieve extra magnification. The revolving nosepiece with objectives is oriented toward the interior – the user can see the objective inserted into the optical path and the space above the stage is free.

Objectives

Infinity plan achromatic objectives and infinity plan fluorite objectives. Standard configuration includes 4x 10x and 100x objectives for brightfield microscopy and a 40x objective for fluorescence microscopy.

Focusing mechanism

Coaxial coarse and fine focusing knobs are located at the base of the microscope on both sides. The user can place their hands on the table and take a relaxed pose while observing. The focusing adjustment is smooth and effortless. On the right there is a coarse focusing lock knob for quick adjustments after changing the specimen. On the left there is a coarse tension adjustment ring for further adjustment.

Stage

The stage does not have an X-axis positioning rack which ensures its ergonomic operation. The mechanical stage with a belt-driven mechanism allows for the smooth movement of the object. The slide holder is fixed with two screws and can be removed for easy operation. For reflected light observations a black stage plate should be placed on the stage to remove stray light.

Reflected light illuminator

The fluorescence excitation source is a 100W mercury lamp. It is extremely bright and has a wide spectrum of wavelengths. The mercury lamp has discrete peaks allowing you to work with many fluorochromes. The reflected light illuminator contains four excitation filters: ultraviolet (UV) violet (V) blue (B) and green (G). The mercury lamp is located in the lamphouse and can be centered in three planes. The heat radiation is conducted away from the lamphouse so that the lamp does not overheat. There is a mount that allows for safe and quick lamp replacement.

Köhler illumination in reflected and transmitted light

Setting up the Köhler illumination enhances the image quality of a specimen. With such illumination you can achieve maximum resolution on each objective and uniform illumination of the field of view with no darkening at the edges. The object of study is in sharp focus and the image artifacts are removed.

Condenser

The condenser has a slot for a darkfield slider or a phase contrast slider. The usage of slider saves time when switching between microscopy techniques in transmitted light.

Transmitted light source

The transmitted light illuminator has a 30W halogen bulb. Halogen bulbs emit light with a color temperature that allows for comfortable work. The 30W bulb is bright enough to observe using 4x to 100x magnification objectives.

Accessories

There is a line of accessories designed for the microscope. Optional objectives provide additional magnification. The optional 10x/0.35 fluorite objective is used for capturing an image of a specimen with a resolution of 0.5μm over a large field of view. Eyepieces that extend the magnification range of the microscope. Optional eyepieces help you maximize the potential of the objective you use most often. A phase contrast device a darkfield condenser and a polarization device offer more microscopy techniques so that you can study the specimens that are invisible in brightfield or fluorescent light. A digital camera that outputs the microscope image on a monitor and stores files along with software that takes real-time measurements of specimens. A calibration slide for measuring objects that can be combined with an eyepiece with a scale or the camera software.

Key features of the microscope:

  • Study of specimens emitting fluorescence when exposed to excitation light
  • Microscopy techniques: fluorescence in reflected light brightfield in transmitted light
  • Trinocular head with adjustable eye relief and a vertical tube for mounting a digital camera
  • Reflected light illuminator: 100W mercury lamp of a wide wavelength spectrum
  • Fluorescence filters: ultraviolet (UV) violet (V) blue (B) green (G)
  • Transmitted light illuminator: 30W halogen bulb providing bright natural light
  • Köhler illumination in reflected and transmitted light
  • Simple stage without a positioning rack
  • Wide range of compatible optional accessories

Key features of the camera:

  • The camera operates autonomously without a connection to a PC and via HDMI interface. Can be connected to a PC via Wi-Fi and a USB3.0 interface
  • Auto switching between 4K and Full HD depending on monitor resolution
  • 30fps for observing moving objects recording video and moving the sample without jerkiness or delays
  • SONY Exmor/Starvis color CMOS backlit sensor provides low noise level and high light sensitivity even in low-light conditions. You will get clearer brighter and more color-saturated images
  • Software with photo video recording editing external display functions linear and angular measurements

The kit includes:

  • MAGUS CHD40 Digital Camera (digital camera HDMI cable (1.5m) USB3.0 cable (1.5m) USB mouse 32GB SD memory card USB Wi-Fi adapter (2pcs.) AC power adapter 12V/1A (Euro) installation CD with drivers and software user manual and warranty card)
  • MAGUS MCD40 LCD Monitor
  • Base with a power input transmitted light source and condenser focusing mechanism stage and revolving nosepiece
  • Reflected light illuminator
  • Mercury lamphouse
  • Trinocular head
  • Infinity plan achromatic objective: PL 4x/0.10 WD 19.8mm
  • Infinity plan achromatic objective: PL 10x/0.25 WD 5.0mm
  • Infinity plan achromatic objective fluo: PL FL 40x/0.85 (spring-loaded) WD 0.42mm
  • Infinity plan achromatic objective fluo: PL 100x/1.25 (spring-loaded oil) WD 0.36mm
  • Eyepiece 10x/22mm with long eye relief (2 pcs.)
  • UV shield
  • C-mount adapter 1x
  • Hex key wrench
  • Mercury lamphouse power supply
  • Power cord
  • Reflected light illuminator power cord
  • Dust cover
  • User manual and warranty card

Available on request:

  • 10x/22mm eyepiece with a scale
  • 12.5x/14mm eyepiece (2 pcs.)
  • 15x/15mm eyepiece (2 pcs.)
  • 20x/12mm eyepiece (2 pcs.)
  • 25x/9mm eyepiece (2 pcs.)
  • Infinity plan achromatic objective fluo: PL FL 10x/0.35 WD 2.37mm
  • Infinity plan achromatic objective: PL 60x/0.80 ∞/0.17 WD 0.46mm
  • Phase contrast device
  • Darkfield condenser
  • Immersion darkfield condenser
  • Darkfield slider
  • Polarization device
  • Calibration slide
Brand MAGUS
Warranty years 5
EAN 5905555018164
Package size (LxWxH) cm 45.2x30.2x96
Shipping Weight kg 16.5
Head trinocular
Head inclination angle 30 °
Eyepiece tube diameter mm 30
Objectives infinity plan achromatic and infinity plan achromatic fluo: PL 4x/0.10; PL 10x/0.25; PL FL 40x/0.85; PL 100x/1.25 (oil); parfocal distance: 45mm (*optional: PL FL 10x/0.35; PL 60x/0.80 ∞/0.17)
Revolving nosepiece for 5 objectives
Working distance mm 19.8 (4x); 5.0 (10x); 0.42 (FL 40x); 0.36 (100x); 2.37 (FL 10х); 0.46 (60х)
Interpupillary distance mm 48 — 75
Stage mm 180x150
Stage moving range mm 75/50
Condenser Abbe condenser N.A. 1.25 center-adjustable height-adjustable adjustable aperture diaphragm a slot for a darkfield slider and phase contrast slider dovetail mount
Diaphragm adjustable aperture diaphragm adjustable iris field diaphragm
Focus coaxial coarse focusing (21mm 39.8mm/circle with a lock knob and tension adjusting knob) and fine focusing (0.002mm)
Brightness adjustment yes
Light source type reflected light: mercury lamp 100W; transmitted light: 12V 30W halogen bulb
Operating temperature range °C 5 — 35
Assembly and installation difficulty level complicated
Fluorescent module filters: ultraviolet (UV) violet (V) blue (B) green (G)
Fluorescence filter: filter type excitation wavelength/dichroic mirror/emission wavelength ultraviolet (UV) 320–380nm/425 nm/435 nm; violet (V) 380–415nm/455nm/475nm; blue (B) 450–490nm/505nm/515nm; green (G) 495–555nm/585nm/595nm
Illumination location dual
Sensor Sony Exmor/Starvis CMOS
Color/monochrome color
Megapixels 8
Maximum resolution pix 3840x2160
Sensor size 1/1.2'' (11.14x6.26mm)
Pixel size μm 2.9x2.9
Light sensitivity 1028mV with 1/30s
Signal/noise ratio 0.13mV at 1/30s
Exposure 0.14ms–1000ms
Video recording yes
Image format *.jpg *.tif
Spectral range nm 380–650 (built-in IR filter)
Shutter type ERS (electronic rolling shutter)
Software HDMI: built-in; USB: MAGUS View
System requirements Windows 8/10/11 (32bit and 64bit) Mac OS X Linux up to 2.8GHz Intel Core 2 or higher minimum 4GB RAM USB2.0 port RJ45 CD-ROM 19' or larger display
Mount type C-mount
Camera power supply DC adapter 12V 1A
Camera operating temperature range °С -10 — 50
Operating humidity range % 30 — 80
Type biological light/optical digital
Nozzle Gemel head (Siedentopf 360° rotation)
Magnification x 40–1000 basic (*optional: 40–1250/1500/2000/2500)
Eyepieces 10х/22mm eye relief: 10mm (*optional: 10x/22mm with scale 12.5x/14; 15x/15; 20x/12; 25x/9)
Stage features two-axis mechanical stage without a positioning rack
Illumination halogen fluorescent
Power supply AC network 85–265V 50/60Hz
Ability to connect additional equipment phase contrast device (condenser and objectives) darkfield condenser (dry or oil) polarization devices (polarizer and analyzer) darkfield slider
User level experienced users professionals
Application laboratory/medical
Research method bright field fluorescence
Pouch/case/bag in set dust cover
Interface connectors Wi-Fi HDMI 1.4 USB3.0
Memory card SD up to 32GB
Ability to connect additional equipment USB mouse flash stick (USB) Wi-Fi adapter (USB)
Frame rate fps at resolution 30@3840х2160 (HDMI) 30@1920х1080 (Wi-Fi) 30@3840х2160 (USB3.0)
Place of installation trinocular tube eyepiece tube instead of an eyepiece
Video format *.h264/*.h265 *.mp4
Body CNC aluminum alloy
Specifications of the AC power adapter input: AC voltage 100–240V 50/60Hz; output: DC voltage 12V/1A

Returns Policy

We have a 14-day return policy. If you are not satisfied with your purchase, please return it in its original packaging and be sure to put the original product packaging inside the shipping box to avoid any damage..

All items must be in their original condition and unused. The value of your purchase will be refunded. .

Shipping charges will not be refunded.

If the return is due to a defective product, you may be compensated for the return shipping.

Please contact us for more details if you need to make a return..

SHIPPING POLICY

- From 0 to 2 kg - shipping cost: 12,50 euros.

- From 2.001 kg to 30 kg - shipping cost: 17,00 euros.

- From 30,001 kg - shipping cost: 30,00 euros.

In case of collection at our warehouse or resale points - the shipping is free.

Related Products