MAGUS Lum D400 Fluorescence Digital Microscope
- €4,958.97
- €4,958.97
- Unit price
- per
Fast Shipping
Most of our order are shipped in 2 working days*
Most of our order are shipped in 2 working days*
We have a 14-day return policy. If you are not satisfied with your purchase, please return it in its original packaging and be sure to put the original product packaging inside the shipping box to avoid any damage. All items must be in their original condition and unused. The value of your purchase will be refunded. Shipping charges will not be refunded.
The microscope is designed for studying specimens using the fluorescence microscopy technique in reflected light and brightfield technique in transmitted light. The additional equipment allows for darkfield polarization and phase contrast microscopy. Fluorescence microscopy is based on the ability of some substances to glow when exposed to the light of a certain part of the spectrum. The specimens are exposed to invisible short-wave ultraviolet light or violet blue and green light. The wavelength of the emitted light will be longer than the wavelength of the excitation light. The specimen glows blue cyan green-yellow or red light respectively. Some specimens glow by themselves while others glow after treatment with fluorochromes. The fluorescent microscope is used to study pathogens of tuberculosis chlamydia rabies herpes and other diseases. The microscope can also be used for DNA and chromosome analysis bone marrow and blood smears forensic and pharmacological examination veterinary control studies and sanitary and epidemiological inspection.
Digital camera
The MAGUS CLM10 digital camera is designed for use in fluorescence and darkfield microscopy techniques. The camera is equipped with a 2.3MP sensor and produces realistic images at a resolution of 1920х1200px. It is recommended for 40x 60x and 100x objectives. When observing with medium magnification objectives the camera will show finer details. Video is recorded at 120fps at maximum resolution. Videos are smooth with soft and subtle transitions between frames. The movement of the object is displayed in real time with no delays. The camera makes it easy to work with objects that are moving and is suitable for classroom demonstrations. The camera is equipped with a USB3.0 interface. The data transfer speed is 10 times faster than USB2.0 cameras. The high-speed camera is recommended for professional laboratories research or university training.
Microscope head
Trinocular head with infinity-corrected optics. Eyepiece tubes can rotate 360°. The user can adjust eye relief on the eyepiece to fit their height. The digital camera is mounted in the trinocular tube.
Revolving nosepiece
Five objectives. A free slot is used for centering the reflected light source. An additional objective can also be installed in the free slot in order to achieve extra magnification. The revolving nosepiece with objectives is oriented toward the interior – the user can see the objective inserted into the optical path and the space above the stage is free.
Objectives
Infinity plan achromatic objectives and infinity plan fluorite objectives. Standard configuration includes 4x 10x and 100x objectives for brightfield microscopy and a 40x objective for fluorescence microscopy.
Focusing mechanism
Coaxial coarse and fine focusing knobs are located at the base of the microscope on both sides. The user can place their hands on the table and take a relaxed pose while observing. The focusing adjustment is smooth and effortless. On the right there is a coarse focusing lock knob for quick adjustments after changing the specimen. On the left there is a coarse tension adjustment ring for further adjustment.
Stage
The stage does not have an X-axis positioning rack which ensures its ergonomic operation. The mechanical stage with a belt-driven mechanism allows for the smooth movement of the object. The slide holder is fixed with two screws and can be removed for easy operation. For reflected light observations a black stage plate should be placed on the stage to remove stray light.
Reflected light illuminator
The fluorescence excitation source is a 100W mercury lamp. It is extremely bright and has a wide spectrum of wavelengths. The mercury lamp has discrete peaks allowing you to work with many fluorochromes. The reflected light illuminator contains four excitation filters: ultraviolet (UV) violet (V) blue (B) and green (G). The mercury lamp is located in the lamphouse and can be centered in three planes. The heat radiation is conducted away from the lamphouse so that the lamp does not overheat. There is a mount that allows for safe and quick lamp replacement.
Köhler illumination in reflected and transmitted light
Setting up the Köhler illumination enhances the image quality of a specimen. With such illumination you can achieve maximum resolution on each objective and uniform illumination of the field of view with no darkening at the edges. The object of study is in sharp focus and the image artifacts are removed.
Condenser
The condenser has a slot for a darkfield slider or a phase contrast slider. The usage of slider saves time when switching between microscopy techniques in transmitted light.
Transmitted light source
The transmitted light illuminator has a 30W halogen bulb. Halogen bulbs emit light with a color temperature that allows for comfortable work. The 30W bulb is bright enough to observe using 4x to 100x magnification objectives.
Accessories
There is a line of accessories designed for the microscope. Optional objectives provide additional magnification. The optional 10x/0.35 fluorite objective is used for capturing an image of a specimen with a resolution of 0.5μm over a large field of view. Eyepieces that extend the magnification range of the microscope. Optional eyepieces help you maximize the potential of the objective you use most often. A phase contrast device a darkfield condenser and a polarization device offer more microscopy techniques so that you can study the specimens that are invisible in brightfield or fluorescent light. A digital camera that outputs the microscope image on a monitor and stores files along with software that takes real-time measurements of specimens. A calibration slide for measuring objects that can be combined with an eyepiece with a scale or the camera software.
Key features of the microscope:
Key features of the camera:
The kit includes:
Available on request:
Brand | MAGUS |
Warranty years | 5 |
EAN | 5905555018157 |
Package size (LxWxH) cm | 45.2x30.2x96 |
Shipping Weight kg | 16.5 |
Head | trinocular |
Head inclination angle | 30 ° |
Eyepiece tube diameter mm | 30 |
Objectives | infinity plan achromatic and infinity plan achromatic fluo: PL 4x/0.10; PL 10x/0.25; PL FL 40x/0.85; PL 100x/1.25 (oil); parfocal distance: 45mm (*optional: PL FL 10x/0.35; PL 60x/0.80 ∞/0.17) |
Revolving nosepiece | for 5 objectives |
Working distance mm | 19.8 (4x); 5.0 (10x); 0.42 (FL 40x); 0.36 (100x); 2.37 (FL 10х); 0.46 (60х) |
Interpupillary distance mm | 48 — 75 |
Stage mm | 180x150 |
Stage moving range mm | 75/50 |
Condenser | Abbe condenser N.A. 1.25 center-adjustable height-adjustable adjustable aperture diaphragm a slot for a darkfield slider and phase contrast slider dovetail mount |
Diaphragm | adjustable aperture diaphragm adjustable iris field diaphragm |
Focus | coaxial coarse focusing (21mm 39.8mm/circle with a lock knob and tension adjusting knob) and fine focusing (0.002mm) |
Brightness adjustment | yes |
Light source type | reflected light: mercury lamp 100W; transmitted light: 12V 30W halogen bulb |
Operating temperature range °C | 5 — 35 |
Assembly and installation difficulty level | complicated |
Fluorescent module | filters: ultraviolet (UV) violet (V) blue (B) green (G) |
Fluorescence filter: filter type excitation wavelength/dichroic mirror/emission wavelength | ultraviolet (UV) 320–380nm/425 nm/435 nm; violet (V) 380–415nm/455nm/475nm; blue (B) 450–490nm/505nm/515nm; green (G) 495–555nm/585nm/595nm |
Illumination location | dual |
=== Delimiter === | Camera specifications |
Sensor | SONY Exmor CMOS |
Color/monochrome | monochrome |
Megapixels | 2.3 |
Maximum resolution pix | 1920х1200 |
Sensor size | 1/1.2' (11.25x7.03) |
Pixel size μm | 5.86x5.86 |
Light sensitivity | 1016mV with 1/30s |
Signal/noise ratio | 0.15mV at 1/30s |
Exposure | 0.244ms–2s |
Video recording | yes |
Video recording | yes |
Image format | *.jpg *.bmp *.png *.tif |
Spectral range nm | 380–650 (with IR filter and anti-reflective filter) |
Shutter type | Global shutter |
Software | MAGUS View |
System requirements | Windows 8/10/11 (32bit and 64bit) Mac OS X Linux up to 2.8GHz Intel Core 2 or higher minimum 2GB RAM USB3.0 port CD-ROM 17' or larger display |
Mount type | C-mount |
Camera power supply | DC 5V from computer USB port; a 12V 3A adapter for Peltier element |
Camera operating temperature range °С | -10 — 50 |
Operating humidity range % | 30 — 80 |
Type | biological light/optical digital |
Nozzle | Gemel head (Siedentopf 360° rotation) |
Magnification x | 40–1000 basic (*optional: 40–1250/1500/2000/2500) |
Eyepieces | 10х/22mm eye relief: 10mm (*optional: 10x/22mm with scale 12.5x/14; 15x/15; 20x/12; 25x/9) |
Stage features | two-axis mechanical stage without a positioning rack |
Illumination | halogen fluorescent |
Power supply | AC network 85–265V 50/60Hz |
Ability to connect additional equipment | phase contrast device (condenser and objectives) darkfield condenser (dry or oil) polarization devices (polarizer and analyzer) darkfield slider |
User level | experienced users professionals |
Application | laboratory/medical |
Research method | bright field fluorescence |
Pouch/case/bag in set | dust cover |
Frame rate fps at resolution | 120@1920x1200 |
Place of installation | trinocular tube eyepiece tube instead of an eyepiece |
Video format | output: *.wmv *.avi *.h264 (Windows 8 and later) *h265 (Windows 10 and later) |
White balance | automatic/manual |
Exposure control | automatic/manual |
Software features | image size brightness exposure time |
Output | USB 3.0 5Gb/s |
Body | CNC aluminum alloy |
We have a 14-day return policy. If you are not satisfied with your purchase, please return it in its original packaging and be sure to put the original product packaging inside the shipping box to avoid any damage..
All items must be in their original condition and unused. The value of your purchase will be refunded. .
Shipping charges will not be refunded.
If the return is due to a defective product, you may be compensated for the return shipping.
Please contact us for more details if you need to make a return..
- From 0 to 2 kg - shipping cost: 12,50 euros.
- From 2.001 kg to 30 kg - shipping cost: 17,00 euros.
- From 30,001 kg - shipping cost: 30,00 euros.
In case of collection at our warehouse or resale points - the shipping is free.
Thanks for subscribing!
This email has been registered!