We have a 14-day return policy. If you are not satisfied with your purchase, please return it in its original packaging and be sure to put the original product packaging inside the shipping box to avoid any damage. All items must be in their original condition and unused. The value of your purchase will be refunded. Shipping charges will not be refunded.
The Ermenrich Zing DZ60 is a True RMS digital clamp meter that is designed for building maintenance engineers, data center specialists, and HVAC (heating, ventilation, and air conditioning) technicians. The model enables in-depth energy audits and current measurements up to 1,000A without shutting down power at the facility.
True RMS: accurate readings with distorted waveforms
Switching power supplies, dimmers, LED lamps, and inverters distort current and voltage waveforms. Clamp meters without True RMS are designed for pure sine waves and can produce errors in such networks. The Ermenrich Zing DZ60 calculates the true root mean square value and accurately measures AC current and voltage in offices, server rooms, and facilities with LED lighting.
Energy audits and HVAC systems
The 30mm jaw opening and AC/DC current measurement up to 1,000A make it easy to test the main incoming cables, check phase distribution, and verify the operation of high-power UPS systems or solar power plants. The thermocouple (up to +1,000°C) makes this clamp meter indispensable for HVAC specialists. It conveniently monitors compressor temperatures, refrigerant lines, and radiators as well as helps to locate overheated contacts in electrical panels.
High resolution and component-level repair
The 6,000-count display provides excellent measurement resolution. Three-phase network voltage (up to 750V AC and up to 800V DC) is displayed with tenths of a volt without switching to a higher range. The device easily replaces a multimeter for PCB repair. It measures the capacitance of start capacitors (up to 100µF), analyzes PWM signals using the frequency meter (up to 10MHz), and identifies faulty diodes as well as instantly locates open circuits thanks to the sensitive continuity test (< 100Ω).
Reliability in any conditions
The clamp meter operates reliably at temperatures from –10°C to +50°C, making it suitable for use on unheated premises as well as outdoors during transitional seasons. The bright screen backlight is invaluable in dark basements and de-energized rooms. User safety is ensured by the CAT III 600V rating. The device is powered by a single 9V battery (purchased separately), and an auto-off function preserves battery life during prolonged inactivity.
Key features:
The kit includes:
| Brand | Ermenrich |
| Warranty | 5 years |
| EAN | 5905555028743 |
| Package size (LxWxH) | 22x11x6 cm |
| Shipping Weight | 0.55 kg |
| Selection of the measuring limit | automatic, manual |
| Basic functions | ammeter, capacitance meter, duty cycle meter, frequency meter, ohmmeter, thermocouple, voltmeter |
| DC voltage measuring limit | 600mV: accuracy ±(0.8%+3); 6V/60V/600V: accuracy ±(1.5%+3); 800V: accuracy ±(2.0%+3) |
| AC voltage measuring limit | 600mV: accuracy ±(0.8%+20); 6V/60V/600V: accuracy ±(1.8%+5); 750V: accuracy ±(2.5%+5) |
| DC current measuring limit | 60A: accuracy ±(2.8%+10); 600A: accuracy ±(2.8%+8); 1,000A: accuracy ±(3.0%+5) |
| AC current measuring limit | 60A: accuracy ±(3.0%+10); 600A: accuracy ±(3.0%+8); 1,000A: accuracy ±(3.0%+5) |
| Resistance measuring limit | 600Ω: accuracy ±(1.0%+4); 6kΩ/60kΩ/600kΩ: accuracy ±(1.5%+2); 6MΩ: accuracy ±(2.5%+3); 60MΩ: accuracy ±(3.5%+5) |
| Capacity measuring limit | 40nF: accuracy ±(5.0%+100); 400nF: accuracy ±(3.0%+5); 4µF/40µF: accuracy ±(3.5%+5); 100µF: accuracy ±(5.0%+5) |
| Frequency measurement limits | 10Hz: accuracy ±(1.5%+5); 100Hz/1kHz/10kHz/100kHz/1MHz/10MHz: accuracy ±(1.2%+2) |
| Duty cycle measurement range | 0.5–99.0%: accuracy ±(1.2%+2) |
| Temperature measurement range | –20...+1,000°C: accuracy ±(3%+5°C) |
| Wire mapping | yes |
| Continuity test | +, threshold <100Ω, test current <1mA |
| Diodes test | yes |
| Diode test | +, test current 0.3mA, open-circuit voltage 1.5V DC |
| True RMS | yes |
| Hold function | yes |
| Limit value function (Min/Max) | yes |
| DCA Zero | yes |
| Input impedance | 7.8MΩ (DC and AC) |
| Throughput capacitance | 50/60Hz (AAC/VAC) |
| Display | yes |
| Display counts | 6000 |
| Display backlight | yes |
| Safety standards | IEC 61010-1 |
| Overvoltage category | CAT III 600V |
| Operating temperature range, °C | -10 — 50 |
| Power supply | 9V battery – 1 pc. (not included) |
| Auto power off | yes |
We have a 14-day return policy. If you are not satisfied with your purchase, please return it in its original packaging and be sure to put the original product packaging inside the shipping box to avoid any damage..
All items must be in their original condition and unused. The value of your purchase will be refunded. .
Shipping charges will not be refunded.
If the return is due to a defective product, you may be compensated for the return shipping.
Please contact us for more details if you need to make a return..
- From 0 to 2 kg - shipping cost: 12,50 euros.
- From 2.001 kg to 30 kg - shipping cost: 17,00 euros.
- From 30,001 kg - shipping cost: 30,00 euros.
In case of collection at our warehouse or resale points - the shipping is free.
Thanks for subscribing!
This email has been registered!